Abstract

The risk of circulatory system depression during the application of new kidney-replacement methods is nowadays considerably lower. It is suggested that haemofiltration exerts a favourable influence upon haemodynamics. The aim of the study was the evaluation of circulatory system stability during high volume continuous veno-venous haemofiltration in patients with acute renal failure after operations in cardiopulmonary bypass, or in the course of acute myocardial infarction.The group of 14 patients with acute renal failure after cardiosurgery or in the course of myocardial infarction underwent the examinations of haemodynamics on the basis of the measurements of stroke volume with thermodilution, during the first 24 hours of high volume continuous veno-venous haemofiltration. The cellulose triacetate filter of 1.9 m2, area and maximum size of penetrating particles of 50000 Daltones was applied.After 24 hours of haemofiltration, the increase of arterial blood pressure was observed, in the circumstances of identical supply of inotropic drugs and identical left and right ventricular filling pressures. The values of both systemic and pulmonary vascular resistance, observed after 12, 18 and 24 hours were higher than the initial values. 6 hours after the beginning of haemofiltration, heart rate increased temporarily, which was associated with a slight decrease of stroke index. The latter as well as cardiac index were slightly lower after 12 hours of haemofiltration when compared with their initial values. Apart from higher systolic, diastolic and mean arterial blood pressure after 24 hours of haemofiltration, there was a statistically insignificant increase of left ventricular stroke work index. High volume continuous veno-venous haemofiltration in patients with multiple organ failure as a result of cardiac insufficiency following the operations in cardiopulmonary bypass or in the course of acute myocardial infarction neither intensifies nor leads to the disorders from circulatory system. The increase of arterial blood pressure after 24 hours of haemofiltration with unchanged values of left and right ventricle filling pressure and a continuous supply of inotropic drugs, suggests that its cause may be the removal of inflammatory reaction mediators and substances of cardiodepressive activity.The method of haemofiltration applied during the present study is well tolerated haemodynamically in patients with multiple organ failure after cardiosurgery or in the course of myocardial infarction.

Keywords: veno-venous haemofiltration, Multiple Organ Failure

Add Comment 0 Comments

Editorial

01 March 2024 : Editorial  

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-Thalassemia

Dinah V. Parums

DOI: 10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

In Press

18 Mar 2024 : Clinical Research  

Sexual Dysfunction in Women After Tibial Fracture: A Retrospective Comparative Study

Med Sci Monit In Press; DOI: 10.12659/MSM.944136  

0:00

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

Most Viewed Current Articles

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750