23 October 2023>: Clinical Research
Comparative Evaluation of Metallic and Biodegradable Suture Anchors in Arthroscopic Repair of Anterior Talofibular Ligament Injury: A Short-term Study on Clinical and Functional Outcomes
Lei Zhang 12ABG , Xiaogao Tang 3ABC , Guixuan You 4BCDE , Xueyi Chen 5EF , Siyi Yang 3DF , Houyin Shi 12F , Guoyou Wang 1AE*DOI: 10.12659/MSM.939830
Med Sci Monit 2023; 29:e939830
Figure 2 (A) Standard anterolateral and anteromedial ankle arthroscopic approaches were established. (B) Use the probe hooks to detect ATFL (red arrow) damage ( fibula, Talus). (C). The double suture anchor was inserted into the middle of the fibula footprint area. (D) Confirm the pull-out resistance of the anchor by pulling the anchor wire. (E) Use nylon wire to guide the anchor wire through the ATFL. (F) Confirm the effectiveness of the suture under the arthroscopic visualization and check the stability of the ankle ( fibula, Talus). All figures were created using PS (Adobe Photoshop CC, Adobe Systems, California, USA).