Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

15 March 2026 : Laboratory Research  

Effect of Argon Plasma and Sandblasting on Bond Strength of PEEK and PEKK to Resin Cement

Verda Gökçe Çakar ORCID logo ABCDEF 1*, İbrahim Halil Tacir ORCID logo ABCDEF 2, Zelal Seyfioğlu Polat ORCID logo ABCDEF 2

DOI: 10.12659/MSM.950955

Med Sci Monit 2026; 32:e950955

Figure 4 EDS analysis graph of PEEK (A) and PEKK (B) samples of the argon plasma.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750