Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

01 February 2011

Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea

Ahmed S BaHammamADEFG, Munir SharifBC, Divinagracia E. GacuanBD, Smitha GeorgeBD

DOI: 10.12659/MSM.881379

Med Sci Monit 2011; 17(2): MT13-19

Abstract

Background: ApneaLink™ (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL’s usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG).
Material/Methods: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3±12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow.
Results: The mean apnea hypopneas index (AHI) for PSG was 34.1±32.4/hr. The AL Auto-AHI was 20.1±25.2/h, and the AL Manual-AHI was 39.5±30.4/h. The Pearson correlation coefficients were r=0.883 between PSG-AHI and AL Auto-AHI, and r=0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80.
Conclusions: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink™ provides good diagnostic agreement with conventional PSG recordings.

Keywords: Pulmonary Ventilation - physiology, Predictive Value of Tests, Polysomnography, Monitoring, Ambulatory - instrumentation, Demography, Adolescent, ROC Curve, Sensitivity and Specificity, Sleep Apnea, Obstructive - physiopathology, young adult

Add Comment 0 Comments

Editorial

01 February 2025 : Editorial  

Editorial: Current Approaches to Screening for Lung Cancer in Smokers and Non-Smokers

Dinah V. Parums

DOI: 10.12659/MSM.948255

Med Sci Monit 2025; 31:e948255

0:00

In Press

Clinical Research  

Procedure Dynamics in Transfemoral vs Transradial Cerebral Angiography: A Retrospective Study

Med Sci Monit In Press; DOI: 10.12659/MSM.947603  

Clinical Research  

Predicting Cerebral Small Vessel Disease Burden Based on Thromboelastography in Patients with Acute Ischemi...

Med Sci Monit In Press; DOI: 10.12659/MSM.946303  

Clinical Research  

Long-Term Outcomes of Implanon in Managing Adenomyosis: A 3-Year Prospective Study

Med Sci Monit In Press; DOI: 10.12659/MSM.945972  

Laboratory Research  

Linear Dimensional Accuracy in Maxillomandibular Records: A Comparative Study of Scannable and Transparent ...

Med Sci Monit In Press; DOI: 10.12659/MSM.947265  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,969,932

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   701,896

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   25,741

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   20,253

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750