Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

20 February 2012

Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma

Jaromir T. WasylukABCDEF, Irmina Jankowska-LechAD, Barbara Terelak-BorysAD, Iwona Grabska-LiberekADE

DOI: 10.12659/MSM.882525

Med Sci Monit 2012; 18(3): CR203-207

Abstract

Background: We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry.
Material/Methods: Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs.
Results: The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices.
Conclusions: Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.

Keywords: Retinal Ganglion Cells - pathology, Ophthalmoscopy, Glaucoma, Open-Angle - pathology, Adolescent, Scanning Laser Polarimetry - methods, Tomography, Optical Coherence - methods, young adult

Add Comment 0 Comments

Editorial

01 March 2025 : Editorial  

Editorial: The World Health Organization (WHO) Updated List of Emerging and Potentially Pandemic Pathogens Includes Yersinia pestis as Plague Vaccines Await Clinical Trials

Dinah V. Parums

DOI: 10.12659/MSM.948672

Med Sci Monit 2025; 31:e948672

0:00

In Press

Clinical Research  

Exploring the Association Between Serum Neurogranin, Nardilysin, and Ischemic Stroke: A Case-Control Study ...

Med Sci Monit In Press; DOI: 10.12659/MSM.947703  

0:00

Clinical Research  

Comparative Analysis of Laser Therapies for Striae Distensae: Fractional CO₂ vs Combined Q-Switch Nd:YAG

Med Sci Monit In Press; DOI: 10.12659/MSM.947464  

Database Analysis  

Utility of Central Venous Oxygen Saturation Gradient in Predicting Mortality in Dialysis with Catheter Access

Med Sci Monit In Press; DOI: 10.12659/MSM.947298  

Clinical Research  

Intraoperative Renal Near-Infrared Spectroscopy Monitoring as a Predictor of Renal Outcomes in Cardiac Surgery

Med Sci Monit In Press; DOI: 10.12659/MSM.947462  

Most Viewed Current Articles

17 Jan 2024 : Review article   7,110,480

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   702,343

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   27,671

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   21,887

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750