Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

28 June 2012

Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms

Zbigniew SerafinABCDEF, Piotr StrześniewskiBDE, Władysław LasekEFG, Wojciech BeuthBEF

DOI: 10.12659/MSM.883199

Med Sci Monit 2012; 18(7): MT60-65

Abstract

Background: The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms.
Material/Methods: Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined.
Results: The sensitivity of TOF-MRA was 85% (95% CI, 65–96%) and of TRICKS, 89% (95% CI, 70–97%). The specificity of both methods was 91% (95% CI, 79–98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86–0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74–0.80).
Conclusions: In this study, TOF-MRA and TRICKS presented similar diagnostic performance; therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.

Keywords: Kinetics, Intracranial Aneurysm - therapy, Imaging, Three-Dimensional - methods, Follow-Up Studies, Embolization, Therapeutic, Contrast Media - diagnostic use, Carotid Artery, Internal - radiography, Magnetic Resonance Angiography - standards, Time Factors

Add Comment 0 Comments

974 3

Editorial

01 December 2023 : Editorial  

Editorial: Outbreaks of Post-Pandemic Childhood Pneumonia and the Re-Emergence of Endemic Respiratory Infections

Dinah V. Parums

DOI: 10.12659/MSM.943312

Med Sci Monit 2023; 29:e943312

0:00

In Press

08 Dec 2023 : Clinical Research  

Association Between Influenza Vaccine Uptake and Health Awareness: A Cross-Sectional Questionnaire-Based St...

Med Sci Monit In Press; DOI:  

04 Dec 2023 : Animal Research  

Effects of Intrathecal Ketamine on Cerebrospinal Fluid Levels of Brain-Derived Neurotrophic Factor and Mech...

Med Sci Monit In Press; DOI:  

01 Dec 2023 : Clinical Research  

Risk Factors and Clinical Outcomes of COVID-19 Infection in Multiple Sclerosis Patients: A Retrospective St...

Med Sci Monit In Press; DOI:  

30 Nov 2023 : Review article  

Decoding the Neurological Sequelae of General Anesthesia: A Review

Med Sci Monit In Press; DOI:  

Most Viewed Current Articles

13 Nov 2021 : Clinical Research  

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

30 Dec 2021 : Clinical Research  

Retrospective Study of Outcomes and Hospitalization Rates of Patients in Italy with a Confirmed Diagnosis o...

DOI :10.12659/MSM.935379

Med Sci Monit 2021; 27:e935379

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

08 Mar 2022 : Review article  

A Review of the Potential Roles of Antioxidant and Anti-Inflammatory Pharmacological Approaches for the Man...

DOI :10.12659/MSM.936292

Med Sci Monit 2022; 28:e936292

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750