Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

28 June 2012

Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms

Zbigniew SerafinABCDEF, Piotr StrześniewskiBDE, Władysław LasekEFG, Wojciech BeuthBEF

DOI: 10.12659/MSM.883199

Med Sci Monit 2012; 18(7): MT60-65

Abstract

Background: The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms.
Material/Methods: Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined.
Results: The sensitivity of TOF-MRA was 85% (95% CI, 65–96%) and of TRICKS, 89% (95% CI, 70–97%). The specificity of both methods was 91% (95% CI, 79–98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86–0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74–0.80).
Conclusions: In this study, TOF-MRA and TRICKS presented similar diagnostic performance; therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.

Keywords: Kinetics, Intracranial Aneurysm - therapy, Imaging, Three-Dimensional - methods, Follow-Up Studies, Embolization, Therapeutic, Contrast Media - diagnostic use, Carotid Artery, Internal - radiography, Magnetic Resonance Angiography - standards, Time Factors

Add Comment 0 Comments

Editorial

01 December 2024 : Editorial  

Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical Research

Dinah V. Parums

DOI: 10.12659/MSM.947428

Med Sci Monit 2024; 30:e947428

0:00

In Press

Animal Research  

Histological Evaluation of the Effects of Intra-Articular Injection of Caffeic Acid on Cartilage Repair in ...

Med Sci Monit In Press; DOI: 10.12659/MSM.946845  

Clinical Research  

Impact of Clear Aligners vs Conventional Brackets on Oxidant and Antioxidant Levels: A Case-Control Study

Med Sci Monit In Press; DOI: 10.12659/MSM.946419  

Animal Research  

Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis...

Med Sci Monit In Press; DOI: 10.12659/MSM.946624  

Clinical Research  

Shiga Toxin-Producing E. coli and Hemolytic Uremic Syndrome: A Study of the 2022 Outbreak in Turkey

Med Sci Monit In Press; DOI: 10.12659/MSM.946033  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,956,586

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,961,734

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   696,847

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   262,907

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750