22 November 2014 : Original article
Central Cannulation by Seldinger Technique: A Reliable Method in Type A Aortic Dissection Repairs
Laszlo GöbölösABCDEF, Peter UgocsaiCE, Maik FoltanBDE, Alois PhilippABD, Andrea ThrumB, Szabolcs MiskolcziEF, Pietro G. MalvindiEF, Vincenzo di GregorioE, Dimitrios PousiosE, Manoraj NavaratnarajahEF, Sunil K. OhriADEFDOI: 10.12659/MSM.890813
Med Sci Monit 2014; 20:2386-2393
Abstract
BACKGROUND: Extensive type A aortic dissections that involve peripheral great vessels can complicate the choice of a cannulation site for cardiopulmonary bypass. We started to employ direct cannulation of the true lumen on the concavity of the aortic arch by Seldinger technique and evaluated the efficacy of this access technique as an alternative arterial inflow target in aortic surgery.
MATERIAL AND METHODS: Twenty-four consecutive patients (mean age: 59±14 years) underwent type A aortic dissection repair using selective antegrade cerebral perfusion. Direct aortic cannulation was used in 14 cases, subclavian access in 6 patients, and femoral entry in 4 patients. Perioperative factors were evaluated to identify the reliability and eventual benefits of direct cannulation method at the aortic arch.
RESULTS: There were no operative deaths and cumulative 30-day mortality rate was 25% (6). Permanent neurological deficits were not observed; in 1 patient transient changes occurred (4%). Time to reach circulatory arrest was the shortest in the direct access group, with mean 27±11 (CI: 20.6–33.3) min vs. 43±22 (28.0–78.0) min (p=0.058) and 32±8 (23.6–40.4) min (p=0.34) by femoral cannulation and subclavian entry, respectively. Direct arch cannulation resulted in the best renal function in the first 72 h after surgery and similar characteristics were observed in lactic acid levels.
CONCLUSIONS: Ultrasound-guided direct cannulation on the concavity of the aortic arch using a Seldinger technique is a reliable method in dissection repairs. Prompt antegrade perfusion provides not only cerebral but also peripheral organ and tissue protection, which is an advantage in this high-risk group of patients.
Keywords: Aorta, Thoracic - surgery, Aorta - surgery, Cardiovascular Surgical Procedures - methods, Catheterization, Creatinine - metabolism, Demography, Intraoperative Care, Lactic Acid - metabolism, Preoperative Care
Editorial
01 November 2024 : Editorial
Editorial: Artificial Intelligence (AI), Digital Image Analysis, and the Future of Cancer Diagnosis and PrognosisDOI: 10.12659/MSM.947038
Med Sci Monit 2024; 30:e947038
In Press
Clinical Research
Iliac Periosteal Bone Autografting vs Talus Non-Weight-Bearing Surgery in Hepple V Talus Osteochondral Inju...Med Sci Monit In Press; DOI: 10.12659/MSM.944912
Clinical Research
Impact of Different Orthodontic Appliances on Mandibular Condyle, Anterior Region of Mandibular, and Maxill...Med Sci Monit In Press; DOI: 10.12659/MSM.946265
Clinical Research
Risk Factors for Bone Cement Displacement After Percutaneous Kyphoplasty in Osteoporotic Vertebral Fracture...Med Sci Monit In Press; DOI: 10.12659/MSM.945884
Clinical Research
Adipose-Derived Mesenchymal Stem Cells from Arthritis Patients: Differential Modulation of CD4⁺ T Cell Acti...Med Sci Monit In Press; DOI: 10.12659/MSM.945273
Most Viewed Current Articles
17 Jan 2024 : Review article 6,407,835
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,909,112
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 695,529
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 260,637
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074