03 November 2015 : Laboratory Research
Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation
Zhenhua LiaoAC, Guy R. FogelE, Ting PuB, Hongsheng GuD, Weiqiang LiuAGDOI: 10.12659/MSM.896085
Med Sci Monit 2015; 21:3348-3355
Abstract
BACKGROUND: The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF).
MATERIAL AND METHODS: Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P).
RESULTS: Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p<0.05). 3DPD construct resulted in slight increase at the 3 instrumented levels (p>0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (p<0.05). Both 3DPD and 3PDP caused significant reduction of ROM at the arthrodesis level and produced motion increase at the arthroplasty level. For adjacent levels, 3P resulted in markedly increased contribution of both upper and lower adjacent levels (p<0.05). Significant motion increases lower than 3P were only noted at partly adjacent levels in some conditions for 3DPD and 3PDP (p<0.05).
CONCLUSIONS: ACDF eliminated motion within the construct and greatly increased adjacent motion. Artificial cervical disc replacement normalized motion of its segment and adjacent segments. While hybrid conditions failed to restore normal motion within the construct, they significantly normalized motion in adjacent segments compared with the 3-level ACDF condition. The artificial disc in 3-level constructs has biomechanical advantages compared to fusion in normalizing motion.
Keywords: Cadaver, Bone Plates, Biomechanical Phenomena, Cervical Vertebrae - surgery, Diskectomy - methods, Range of Motion, Articular, Stress, Mechanical, Total Disc Replacement - methods, Two-Hybrid System Techniques
Editorial
01 September 2024 : Editorial
Editorial: Reasons for Increasing Global Concerns for the Spread of MpoxDOI: 10.12659/MSM.946343
Med Sci Monit 2024; 30:e946343
In Press
Clinical Research
Prognostic Significance of the Advanced Lung Cancer Inflammation Index in Metastatic Small Cell Lung Cancer...Med Sci Monit In Press; DOI: 10.12659/MSM.945752
Review article
Dangerous Intersection of Alcoholism and Othello Syndrome: A Comprehensive Review of Delusional Jealousy an...Med Sci Monit In Press; DOI: 10.12659/MSM.945616
Clinical Research
Intrathecal Morphine Enhances Postoperative Analgesia and Recovery in Robotic-Assisted Laparoscopic Partial...Med Sci Monit In Press; DOI: 10.12659/MSM.945595
Review article
Pharmacological Strategies in Dermatomyositis: Current Treatments and Future DirectionsMed Sci Monit In Press; DOI: 10.12659/MSM.944564
Most Viewed Current Articles
17 Jan 2024 : Review article 6,043,606
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,830,608
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 692,780
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 257,254
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074