12 January 2018 : Original article  

Factors Causing Disagreement between Measured and Calculated Low Density Lipoprotein-Cholesterol (LDL-C) in Clinical Laboratory Services

Veeravan Lekskulchai1ABCDEF*

DOI: 10.12659/MSMBR.907751

Med Sci Monit Basic Res 2018; 24:10-15

Abstract

BACKGROUND: Since measured low density lipoprotein-cholesterol (LDL-C) has been available in clinical laboratories, there have been concern about the disagreement between measured and calculated LDL-C and the factors causing their disagreement.

MATERIAL AND METHODS: Serum lipid concentrations were collected from 1,339 medical records of patients admitted to hospital between 2013 and 2015. They were grouped by their total cholesterol (TC), triglycerides (TG), and high-density lipoprotein-cholesterol (HDL-C) concentrations and the agreement between measured and calculated LDL-C was statistically analyzed.

RESULTS: A strong relationship was found between measured and calculated LDL-C. Significantly disagreements between measured and calculated LDL-C were found in all groups in 2013 and 2014 when lipids were analyzed by Cobas C501. Disagreements found in groups of low TG and low HDL-C concentrations in 2015 were when lipids were analyzed by Abbott Architect ci8200. In groups of calculated LDL-C <1.81 mmol/L, around 80% had the measured LDL-C >1.81 mmol/L. Among various atherogenic indices, non-HDL-C showed the strongest relationship with LDL-C, while TC to HDL-C ratio showed the strongest agreement with the LDL-C.

CONCLUSIONS: The disagreement between measured and calculated LDL-C in a clinical laboratory seemed to depend on the analytical system used, and was probably associated with individual laboratory variations.

Keywords: Cholesterol, LDL, Coronary Disease, Lipoprotein, HDL

Add Comment 0 Comments

In Press

Clinical Research  

Questionnaire-Based Study of 392 Women in Abbottabad, Pakistan, to Evaluate the Types of Cosmetic Products ...

Med Sci Monit Basic Res In Press; DOI:  

Most Viewed Current Articles

15 Jun 2022 : Clinical Research  

Evaluation of Apical Leakage After Root Canal Obturation with Glass Ionomer, Resin, and Zinc Oxide Eugenol ...

DOI :10.12659/MSMBR.936675

Med Sci Monit Basic Res 2022; 28:e936675

07 Jul 2022 : Laboratory Research  

Cytotoxicity, Apoptosis, Migration Inhibition, and Autophagy-Induced by Crude Ricin from Ricinus communis S...

DOI :10.12659/MSMBR.936683

Med Sci Monit Basic Res 2022; 28:e936683

01 Jun 2022 : Laboratory Research  

Comparison of Sealing Abilities Among Zinc Oxide Eugenol Root-Canal Filling Cement, Antibacterial Biocerami...

DOI :10.12659/MSMBR.936319

Med Sci Monit Basic Res 2022; 28:e936319

17 Jan 2022 : Clinical Research  

Anodal Transcranial Direct Current Stimulation (tDCS) Over the Primary Motor Cortex (M1) Enhances Motor Res...

DOI :10.12659/MSMBR.934180

Med Sci Monit Basic Res 2022; 28:e934180

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor Basic Research eISSN: 2325-4416
Medical Science Monitor Basic Research eISSN: 2325-4416