A Clinical Application Study of Mixed Reality Technology Assisted Lumbar Pedicle Screws Implantation

Yue Gu1CE, Qingqiang Yao2ABD, Yan Xu2CF, Huikang Zhang3BCF, Peiran Wei1BF, Liming Wang2AG*

DOI: 10.12659/MSM.924982

Med Sci Monit 2020; 26:e924982

Table 3 Comparison of efficacy.

Low back pain ODI scoreVAS scores of lower limbs on the affected side
Group AGroup BGroup AGroup B
Preoperative50.35±9.2751.75±9.187.16±1.407.12±1.26
One month after surgery34.44±8.5043.03±9.303.48±1.003.88±1.20
value6.32303.424310.05589.2710
values<0.0010.0013<0.001<0.001
ODI – Oswestry disability index; VAS – visual analog scale.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.