28 November 2020 : Clinical Research
Use of Palpation Imaging in Diagnosis of Breast Diseases: A Way to Improve the Detection Rate
Yihan Ding12ABE, Chenyu Sun3CDEF, Qin Zhou4CD, Ce Cheng5DF, Cunye Yan6AF, Benzhong Wang12AEG*DOI: 10.12659/MSM.927553
Med Sci Monit 2020; 26:e927553
Table 6 Sensitivity of combination tests (parallel test).
| Pathology | Sensitivity (%) | P | ||
|---|---|---|---|---|
| M | B | |||
| PI | ||||
| M | 34 | 14 | 94.4 | 0.493* |
| B | 2 | 67 | ||
| Ultrasound | ||||
| M | 30 | 4 | 83.3 | 0.025** |
| B | 6 | 77 | ||
| Mammography | ||||
| M | 29 | 11 | 80.6 | 0.011# |
| B | 7 | 70 | ||
| Combination | ||||
| M | 36 | 22 | 100.0 | 0.010## |
| B | 0 | 59 | ||
| M – malignant; B – benign. * PI combination; ** ultrasound combination; # mammography combination; ## overall group comparison. | ||||