Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

07 February 2021: Clinical Research

Comparative Analysis of 3D-Printed Artificial Vertebral Body Versus Titanium Mesh Cage in Repairing Bone Defects Following Single-Level Anterior Cervical Corpectomy and Fusion

Tao Fang BCD* , Ming Zhang BC* , Jing Yan BF , Jiali Zhao CF , Wei Pan C , Xinhong Wang E , Quan Zhou ACG*

DOI: 10.12659/MSM.928022

Med Sci Monit 2021; 27:e928022

Table 4 Preoperative and postoperative NDI, JOA, and VAS scores.

Group3D-printed groupTMC groupStatistical analysisp-Value
NDI (scores)
 Pre-OP34.83±3.9735.50±3.72−0.3000.770
 Post-OP 3M17.33±2.1620.83±4.02−1.8780.090
 Post-OP Last7.50±1.5210.17±2.32−2.3590.040
JOA (scores)
 Pre-OP8.17±1.178.67±1.03−0.7850.451
 Post-OP 3M12.50±1.6412.83±1.17−0.4050.694
 Post-OP Last13.67±1.3713.50±1.050.2370.817
VAS (scores)
 Pre-OP7.83±0.988.17±0.75−0.6590.525
 Post-OP 3M6.17±0.756.33±1.21−0.2860.780
 Post-OP Last2.67±1.032.83±0.98−0.2860.780

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.