06 December 2021 : Database Analysis  

Diffusion-Weighted Magnetic Resonance Imaging of 103 Patients with Rectal Adenocarcinoma Identifies the Apparent Diffusion Coefficient as an Imaging Marker for Tumor Invasion and Regional Lymph Node Involvement

Jaromir Kargol1ABCDEF*, Wojciech Rudnicki2CDE, Jakub Kenig3DE, Justyna Filipowska4BE, Ewa Kaznowska5BE, Tomasz Kluz6BE, Wiesław Guz4BE, Elżbieta Łuczyńska4ACDEF

DOI: 10.12659/MSM.934941

Med Sci Monit 2021; 27:e934941

Table 2 Sensitivity, specificity, and accuracy with different apparent diffusion coefficient parameters and values and the respective area under curve. Microsoft Corporation, Microsoft Word 2013 (version 15.0.5389.1000).

VariableAUCp-valueADCSensitivitySpecificityAccuracy
ADC mean0.61577660.0%67.2%64.1%
ADC minimum0.5580.30698542.2%74.1%60.2%
ADC maximum0.5950.09054760.0%58.6%59.2%
ADC – apparent diffusion coefficient; AUC – area under curve.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.