07 September 2022: Clinical Research

Measurement of Serum Levels of 5 Amino Acids and Dimethylamine Using Liquid Chromatography-Tandem Mass Spectrometry in Patients without Septic Associated Acute Kidney Injury and with Septic Associated Acute Kidney Injury Requiring Continuous Renal Replacement Therapy

Patrycja Leśnik 1ABCDEFG* , Lidia Łysenko 2ADEG , Mariusz G. Fleszar 3ABF , Paulina Fortuna 3ABF , Ewa Woźnica-Niesobska 2BCDE , Magdalena Mierzchała-Pasierb 3ABF , Jarosław Janc 1ABCDEFG

DOI: 10.12659/MSM.937784

Med Sci Monit 2022; 28:e937784

Table 6 The AUC of DMA biomarker and creatinine for detection of CRRT patients.

AUCSEAUC lower 95%AUC upper 95%zp-value
DMA [umol/L]0.7320.090.550.912.550.011
Creatinine[mg/dL]0.7020.090.530.882.300.022
AUC – area under the curve; SE – standard error.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.