18 November 2022 : Review article
A Systematic Review of the Literature Between 2009 and 2019 to Identify and Evaluate Publications on the Effects of Age-Related Hearing Loss on Speech Processing
Andrea Cristina de Oliveira Eichner1ABCDEF, Caroline DonadonDOI: 10.12659/MSM.938089
Med Sci Monit 2022; 28:e938089
Table 2 FFR acquisition parameters of the included studies.
| Article | Equipment | Software | Stimulated ear | Stimuli | Duration (ms) | Number of sweeps |
|---|---|---|---|---|---|---|
| Jain et al 2019 []11 | BioLogic-Navigator Pro | Matlab BioMARK | RE/LE | /da/ | 40 | 4000 |
| Heidari et al 2018 []3 | BioLogic Navigator Pro | Matlab BioMARK | RE | /da/ | 40 | 2 blocks of 2000 |
| Ansari et al 2017 []12 | Intelligent Hearing Systems | SmartEP | RE | /da/ | 40 | 2 blocks of 2000 |
| Anderson et al. 2013 []13 | BioLogic Navigator Pro System | Klatt-based synthesizer | RE/LE | /da/ | 40 | 2 blocks of 3000 |
| Clinard and Tremblay 2013 []2 | Neuroscan SynAmps2BioLogic Navigator Pro | Matlab | RE | Tone burst/da/ | 50040 | 2 blocks of 3000 |
| Vander et al 2011 []14 | BioLogic Navigator Pro | Matlab BioMARK | RE/LE | /da/ | 40 | 2 blocks of 1500 |
| Jain et al 2019 []11 | 80 dB SPL | Alternate | 10.1 | ----- | ----- | ----- |
| Heidari et al 2018 []3 | 80 dB SPL | Alternate | 10.9 | 103–125 | 220–720 | 1700–1240 |
| Ansari et al 2017 []12 | 65 dB HL | Alternate | 11.1 | 113–147 | 240–770 | 1670–1350 |
| Anderson et al. 2013 []13 | 80 dB SPL | Alternate | 10.9 | 103–125 | 220–720 | 1700–1240 |
| Clinard and Tremblay 2013 []2 | 80 dB SPL | Alternate | 10.9 | 103–125 | 220–720 | 1700–1240 |
| Vander et al 2011 []14 | 82 dB SPL62 dB SPL | Alternate | 11.1 | 103–121 | 454–719 | 721–1155 |
| RE – right ear; LE – left ear; ms – milliseconds; SPL – sound pressure level; HL – hearing level; dB – decibels; Hz – hertz; F0 – fundamental frequency; F1 – first formant; F2 – second formant. | ||||||