17 October 2022 : Clinical Research  

Comparison of Incremental Shuttle Walking Test, 6-Minute Walking Test, and Cardiopulmonary Exercise Stress Test in Patients with Myocardial Infarction

Ho-Jeong Lim12ABCF, Sung-Ju Jee2BDE, Myung-Mo Lee3ADEG*

DOI: 10.12659/MSM.938140

Med Sci Monit 2022; 28:e938140

Table 3 Comparison of differences in HRmax and RPE according to evaluation methods.

CPXISWT6MWTF (p)
HRmax, beats132.35±18.69* 114.90±15.39# 103.80±12.09# 16.964 (.000)
RPE, scores16.10±1.0214.10±1.02# 12.30±0.97,# 71.266 (.000)
* Data are presented as mean±SD.
6MWT – 6-minutes walking test; CPX – cardiopulmonary exercise test; HRmax – maximum heart rate; ISWT – instrumental shuttle walking test; RPE – rate of perceived exertion.
# Significant difference compared to CPX;
## significant difference compared to ISWT.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.