Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

30 November 2022: Clinical Research

Clinicopathological Features of Breast Cancer in Relation to Exposure of Cycling Reproductive Hormones: A Multicenter Retrospective Study of 14 731 Patients Diagnosed with Invasive Breast Cancer

Jiazheng Sun 1BE , Jinxiang Tan 1BC , Hong Zheng 2B , Jun Jiang 3B , Tianning Zou 4BC , Hongyuan Li 1BF , Guosheng Ren 1BC* , Dejuan Yang 1AG*

DOI: 10.12659/MSM.938619

Med Sci Monit 2022; 28:e938619

Table 1 Comparsion of clinicopathologic characteristics between menarche age <14 yrs and ≥14 yrs breast cancer patients.

Tumor charactersAll patientsPremenopausal patientsPostmenopausal patients
No. of menarche age <14/≥14 (ref) patientsOdds ratio (95% CI)P-valueNo. of menarche age <14/≥14 (ref) patientsOdds ratio (95% CI)P-valueNo. of menarche age <14/≥14 (ref) patientsOdds ratio (95% CI)P-value
 No5129/79331.03283/45001.01846/34331.0
 Yes202/2921.11 (0.65, 1.92)0.7014132/1761.21 (0.57, 2.57)0.61170/1161.05 (0.44, 2.49)0.9192
 Unknown375/507257/283118/224
 Ductal carcinoma4155/67181.02654/38961.01501/28221.0
 Lobular carcinoma123/1910.59 (0.33, 1.03)0.062284/1070.51 (0.23, 1.12)0.094839/840.75 (0.33, 1.71)0.4939
 Medullary carcinoma72/1151.23 (0.32, 4.78)0.76856/771.34 (0.19, 9.54)0.770216/381.29 (0.17, 9.55)0.8044
 Mucinous carcinoma128/17674/9954/77
 Mix90/1480.39 (0.04, 3.50)0.397763/980.40 (0.04, 3.97)0.432227/500.9915
 Unknown1138/1348741/682397/702
 No3119/44081.01938/23711.01181/20371.0
 Yes14/231.35 (0.19, 9.69)0.764110/140.95 (0.06, 15.39)0.97114/92.22 (0.12, 41.56)0.5949
 Unknown2573/43011724/2574849/1727
 No3047/42541896/22861151/1968
 Yes92/1790.98 (0.55, 1.73)0.94559/1061.62 (0.73, 3.57)0.236133/730.55 (0.21, 1.43)0.2205
 Unknown2567/42991708/2567859/1732
 No1618/21531.0993/11111.0625/10421.0
 Yes1401/21020.92 (0.79, 1.08)0.3057852/11710.87 (0.71, 1.07)0.1903549/9310.96 (0.76, 1.21)0.6976
 Unknown2687/44771827/2677860/1800
 I231/3001.0140/1691.091/1311.0
 II2248/31950.92 (0.75, 1.13)0.40831387/1716861/14791.28 (0.93, 1.77)0.1351
 III760/1215469/659291/5561.07 (0.70, 1.64)0.7617
 Unknown2467/40221676/2415791/1607
 T1 (≤20 mm)1616/21901.01002/11901.0614/10001.0
 T2 (20 mm2188/33900.92 (0.62, 1.37)0.68511397/18731.01 (0.57, 1.80)0.9625791/15170.86 (0.49, 1.51)0.5916
 T3 (>50 mm)246/3870.86 (0.49, 1.51)0.6013161/2350.87 (0.40, 1.88)0.717385/1520.85 (0.36, 1.98)0.7035
 T482/16146/850.71 (0.12, 4.24)0.7039508/760.9716
 Unknown1574/26041066/1576508/1028
 N02441/35261.01557/19471.0884/15791.0
 N11151/18180.99 (0.83, 1.19)0.9484763/10620.95 (0.75, 1.21)0.6879388/7561.00 (0.76, 1.31)0.9817
 N2456/7171.09 (0.84, 1.42)0.5119294/4020.96 (0.67, 1.36)0.8002162/3151.26 (0.83, 1.91)0.2863
 N3281/4000.97 (0.69, 1.36)0.8533154/2180.68 (0.40, 1.15)0.1487127/1821.42 (0.90, 2.24)0.1316
 Unknown1377/2271904/1330473/941
 M04254/63621.02723/35731.01531/27891.0
 M143/501.86 (0.60, 5.71)0.279922/232.34 (0.37, 14.90)0.366421/272.63 (0.58, 11.96)0.2105
 Unknown1409/2420927/1363482/957
 ≤15798/10351.0494/5851.0304/4501.0
 >15, ≤20787/10951.11 (0.89, 1.38)0.3774484/5631.31 (0.97, 1.78)0.0836303/5320.92 (0.66, 1.28)0.6109
 >20, ≤301135/16521.06 (0.69, 1.62)0.8029724/8621.37 (0.75, 2.52)0.3098411/7900.73 (0.39, 1.36)0.3248
 >30886/13581.14 (0.74, 1.76)0.5599550/7611.28 (0.69, 2.37)0.4361336/5970.90 (0.47, 1.70)0.737
 Unknown2100/35921421/2188679/1404
 Negetive1979/29751.01230/15831.0749/13921.0
 Positive3487/53540.90 (0.72, 1.13)0.37262278/31340.81 (0.58, 1.13)0.22231209/22191.04 (0.75, 1.43)0.8225
 Unknown240/403164/24276/162
 Negetive2336/34621.01340/18021.0996/18401.0
 Positive3125/46731.13 (0.91, 1.40)0.27532116/29061.15 (0.84, 1.58)0.38181009/17670.97 (0.71, 1.32)0.834
 Unknown245/417166/25179/166
 Negetive2988/44501.01932/25941.01056/18561.0
 Positive1903/28291.06 (0.91, 1.24)0.45561179/14911.00 (0.81, 1.23)0.9819724/13381.17 (0.92, 1.48)0.1936
 Unknown815/1453561/874254/579
 ≤20%1487/20761.0911/10571.0576/10091.0
 >20%1321/18550.99 (0.84, 1.17)0.9147853/10010.90 (0.72, 1.12)0.3569468/8641.03 (0.81, 1.32)0.8157
 Unknown2898/48011908/2901990/1900
 Negative1210/14881.0700/7681.0510/7201.0
 Positive1749/23650.93 (0.79, 1.09)0.38741095/12670.94 (0.75, 1.17)0.5568654/10980.91 (0.71, 1.15)0.4145
 Unknown2747/48791877/2924870/1955

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.