18 June 2023: Clinical Research

Lamina Abrasion Caused by High-Speed Drill in Unilateral Door Cervical Laminoplasty: A Clinical Investigation

Jiwei Zou 1BCEF* , Shuyong Fan 1BCE* , Xingxing Chen 2BCD* , Zhibin Wu 3CDEF , Yongfeng Chen 1ABCE*

DOI: 10.12659/MSM.939939

Med Sci Monit 2023; 29:e939939

Table 1 Pre- and postoperative SCD of patients who underwent unilateral door cervical laminoplasty (x±s, mm).

Preoperative SCDPostoperative SCDPSCD increaseELOEN
C38.96±0.4814.26±0.705.45±0.7510.53±0.91112
C48.94±0.6314.73±0.845.88±0.6710.73±1.01133
C58.72±0.7514.20±0.825.57±0.5610.55±1.09138
C68.73±0.6514.23±0.675.59±0.5410.76±1.05132
C78.81±0.7014.44±0.785.72±0.3010.75±1.1587
C8.84±0.5714.52±0.945.77±0.6810.67±1.23602
SCD – sagittal canal diameter; ELOE – effective laminar opening extent.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.