10 February 2024>: Database Analysis
Association Between Albumin-Corrected Anion Gap and In-Hospital Mortality and Sepsis-Associated Acute Kidney Injury
Haixu Guo 12BCDEF , Jie Wang 13A*DOI: 10.12659/MSM.943012
Med Sci Monit 2024; 30:e943012
Table 3 Comparison of ROC curves.
Factor | AUC | 95% CI | Optimal cut-off | Sensitivity | Specificity | Youden’s index |
---|---|---|---|---|---|---|
ACAG | 0.675 | 0.664~0.685 | >20.25 | 0.5600 | 0.7076 | 0.2675 |
ALB | 0.598 | 0.587~0.609 | ≤2.75 | 0.4369 | 0.7224 | 0.1593 |
AG | 0.648 | 0.637~0.658 | >17.00 | 0.5118 | 0.7151 | 0.2269 |
ALB – albumin; AG – anion gap; ACAG – albumin-corrected anion gap. |