Table 2 Cut-off points and diagnostic values of variables for the distinction between non- appendicitis patients and appendicitis patients.

VariablesCut-offDiagnostic valuesROC curveOdds ratio
SensitivitySpecificityPPVNPVAccuracyArea (SE)95% CIPOdds ratio95% CIP
Ileocolic artery diameter2.47592.6%95.6%95.6%92.6%94.09%0.982 (0.005)0.973–0.991273.306127.318–586.691
Ileocolic vein diameter3.88586.4%97.6%97.4%87.5%91.92%0.972 (0.006)0.960–0.985259.105106.952–627.716
If both are positive83.3%99.2%99.1%85.2%91.14%620148.448–2589.445
PPV – positive predictive value; NPV – negative predictive value; ROC – receiver operating characteristic; SE – standard error.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.