Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

10 July 2024 : Clinical Research  

Assessing the Consequences of Smoking Tobacco Products with Consideration of the Forced Oscillation Technique

Aleksandra Grudzińska ORCID logo1ABCDEF, Paulina Okrzymowska ORCID logo1ABCDEF*, Agata Tomaszczyk ORCID logo1EF, Dariusz Kalka ORCID logo1DEF, Krystyna Rożek-Piechura ORCID logo1ABCDEF

DOI: 10.12659/MSM.944406

Med Sci Monit 2024; 30:e944406

Table 3 Characteristics of the forced oscillation technique (FOT) parameters in the study groups. Unidimensional results for each ZZ parameterization with sigma-limits effective hypothesis decomposition.

ParameterControl groupn=20Cigarette smokersn=20Nicotine alternativeusers n=20p
Rrs 5 Hz Rinsp [%]112.71±46.45114.87±37.38114.22±29.640.04*
Rrs 5 Hz Rexp [%]141.17±70.40128.05±38.81136.29±46.830.06
Rrs 5 Hz Rtot [%]128.48±56.87121.65±37.18125.51±37.450.39
Xrs 5 Hz Xinsp [%]112.71±46.4564.92±26.2187.22±32.410.40
Xrs 5 Hz Xexp [%]141.17±70.4055.21±22.4079.83±38.270.69
Xrs 5 Hz Xtot [%]128.48±46.8759.50±22.5783.35±34.370.51
AX insp [%]97.93±69.2764.14±45.62113.02±108.870.48
Rrs 11 Hz Rinsp [%]108.83±44.93112.41±37.36112.21±24.420.04*
Rrs 11 Hz Rexp [%]143.92±67.76130.20±38.97138.37±41.700.06
Rrs 11 Hz Rtot [%]128.15±55.1121.74±37.33125.73±32.000.47
Xrs 11 Xinsp [%]128.29±275.25258.25±193.03180.92±161.940.76
Xrs 11 Xexp [%]105.18±365.62275.62±228.6196.61±242.550.57
Xrs 11 Xtot [%]106.40±353.33267.57±199.85137.30±195.680.70
* Statistically significant inter-testing session or intergroup difference at the ≤0.05 level.
Rrs 5 Hz Rinsp – inspiratory resistance at 5 Hz; Rrs 5 Hz Rexp – expiratory resistance at 5 Hz; Rrs 5 Hz Rtot – total respiratory resistance at 5 Hz; Xrs 5 Hz Xinsp [%] – inspiratory reactance at 5 Hz; Xrs 5 Hz Xexp [%] – expiratory reactance at 5 Hz; Xrs 5 Hz; Xtot [%] – total reactance at 5 Hz; AX insp – the area under inspiratory reactance curve; Rrs 11 Hz Rinsp – inspiratory resistance at 11 Hz; Rrs 11 Hz Rexp – expiratory resistance at 11 Hz; Rrs 11 Hz Rtot – total respiratory resistance at 11 Hz; Xrs 5 Hz Xinsp [%] – inspiratory reactance at 11 Hz; Xrs 11 Hz Xexp [%] – expiratory reactance at 11 Hz; Xrs 11Hz; Xtot [%] – total reactance at 11 Hz.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750