14 November 2024 : Clinical Research
Risk Factors for Bone Cement Displacement After Percutaneous Kyphoplasty in Osteoporotic Vertebral Fractures: A Retrospective Analysis
Yonghao WuDOI: 10.12659/MSM.945884
Med Sci Monit 2024; 30:e945884
Table 3 Receiver operating characteristic curve of BCD after percutaneous kyphoplasty for OVFs.
| AUC | P | 95% CI | Optimal cutoff value | Sensitivity | Specificity | Youden’s index | |
|---|---|---|---|---|---|---|---|
| BMI | 0.687 | 0.038 | 0.510~0.864 | 25.780 | 0.727 | 0.707 | 0.434 |
| Restoration of the Cobb angle | 0.759 | 0.004 | 0.591~0.927 | 11.095 | 0.818 | 0.701 | 0.519 |
| Distance between bone cement and vertebral endplates | 0.762 | 0.004 | 0.667~0.858 | 0.175 | 1 | 0.539 | 0.539 |
| Bone cement leakage | 0.689 | 0.036 | 0.540~0.839 | – | 0.727 | 0.713 | 0.440 |
| Logistic regression model | 0.928 | <0.001 | 0.840~1.000 | – | 0.909 | 0.910 | 0.819 |