18 January 2025 : Laboratory Research
Effect of Irrigation Solution Temperature on Bioceramic Sealer Bond Strength
Hasret KilivanDOI: 10.12659/MSM.946772
Med Sci Monit 2025; 31:e946772
Table 2 Descriptive statistics of the bond strength values depending on solution, temperature, and section.
| Temperature | Section | Solution | Total | ||
|---|---|---|---|---|---|
| Dual Rinse | EDTA | GA | |||
| 22°C | Apical | 1.0±0.7 | 1.1±0.5 | 0.8±0.3 | 1.0±0.5 |
| Middle | 1.6±0.8 | 1.8±0.7 | 1.4±0.7 | 1.6±0.7 | |
| Total | 1.3±0.8 | 1.4±0.7 | 1.1±0.6 | 1.3±0.7 | |
| 37°C | Apical | 1.3±0.3 | 1.8±0.5 | 1.4±0.7 | 1.5±0.6 |
| Middle | 2.4±0.8 | 3.0±0.6 | 2.8±0.8 | 2.8±0.8 | |
| Total | 1.9±0.8 | 2.4±0.8 | 2.1±1.0 | 2.1±0.9 | |
| Total | Apical | 1.2±0.5 | 1.4±0.6 | 1.1±0.6 | 1.2±0.6 |
| Middle | 2.0±0.9 | 2.4±0.9 | 2.1±1.1 | 2.2±0.9 | |
| Total | 1.6±0.8 | 1.9±0.9 | 1.6±1.0 | 1.7±0.9 | |
| Mean±standard deviation (a-b, x-z: there is no significant difference between values with the same letters). EDTA – ethylenediamine tetra-acetic acid; GA – ghlycolic acid; NaOCl – sodium hypochlorite; Dual Rinse HEDP – etidronate powder. | |||||