Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

08 March 2025 : Laboratory Research  

Evaluation of Surface Roughness of Multilayered Monolithic Zirconia Following Chairside Adjustment with 3 Different Polishing Systems Sterilized for Multiple Cycles: An In Vitro Study

Honey Lunkad ORCID logo ABEFG 1*, Mohammed E. Sayed ORCID logo ABEFG 1, Ali A. Najjar BCDEF 2, Muhannad Halawi ORCID logo BCDEF 2, Yahya Tawhari ORCID logo BCDEF 2, Manar K. Alamri ORCID logo CEFG 3, Saad Saleh AlResayes ORCID logo ACDEG 4, Majed S. Altoman ORCID logo ACDEF 5, Abdullah Hasan Alshehri ORCID logo CDEFG 5, Mohammad Alamri ORCID logo CDEFG 6, Nisreen Nabiel Hassan ORCID logo ACDEF 7, Mai Almarzouki ORCID logo CDEG 8, Abeer Ali Qahtani ORCID logo CDEG 9, Firas K. Alqarawi ORCID logo CDEG 10, Khurshid Ahmed Mattoo ORCID logo ACDEF 1

DOI: 10.12659/MSM.947231

Med Sci Monit 2025; 31:e947231

Table 3 Post-hoc test results for multiple group comparison showing mean rank differences and their level of significance when compared with the control and between various subgroups.

Group1E5E10E1U5U10U1W5W10W
ControlMRD48.05* 36.442.3* 35.3545.9* 49.05* 53.5* 58.3* 35.65
value0.00020.00490.00100.00630.00030.00010.00000.00000.0058
1EMRD0−11.65−5.75−12.7−2.1515.4510.25−12.4
value0.3680.65680.32640.86810.93840.67370.42840.338
5EMRD−11.6505.9−1.059.512.6517.121.9−0.75
value0.3680.64850.93530.46290.32840.18640.090620.9538
10EMRD−5.755.90−6.953.66.7511.216−6.65
value0.65680.64850.59130.78090.6020.38680.21640.6074
1UMRD−12.7−1.05−6.95010.5513.718.1522.950.3
value0.32640.93530.59130.4150.28980.16080.076180.9815
5UMRD−2.159.53.610.5503.157.612.4−10.25
value0.86810.46290.78090.4150.80770.5570.3380.4284
10UMRD112.656.7513.73.1504.459.25−13.4
value0.93840.32840.6020.28980.80770.7310.47480.3005
1WMRD5.4517.111.218.157.64.4504.8−17.85
value0.67370.18640.38680.16080.5570.7310.71070.1678
5WMRD10.2521.91622.9512.49.254.80−22.65
value0.42840.090620.21640.076180.3380.47480.71070.0801
10WMRD−12.4−0.75−6.650.3−10.25−13.4−17.85−22.650
value0.3380.95380.60740.98150.42840.30050.16780.0801
MRD – mean rank differences; 1E – EVE Diacera polishing kit, autoclaved once; 5E – EVE Diacera polishing kit, autoclaved 5 times; 10E – EVE Diacera polishing kit, autoclaved 10 times; 1U – Ultradent Jiffy polishing kit, autoclaved once; 5U – Ultradent polishing kit, autoclaved 5 times; 10U – Ultradent polishing kit, autoclaved 10 times; 1W – SS White polishing kit, autoclaved once; 5W – SS White polishing kit, autoclaved 5 times; 10W – SS White polishing kit, autoclaved 10 times. Post-hoc multiple comparison (Dunn test) after Bonferroni’s correction ( value/n).
* All significant values denoted as are significant at the value of ≤0.0011. (Corrected α=α/m=0.05/45=0.001111, where α is the value and m is the number of total subgroups).

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750