11 April 2025 : Laboratory Research
In Vitro Assessment of Linear Dimensional Accuracy of Polyvinyl Siloxane-Based Computer-Aided Design and Transparent Interocclusal Record Materials at 3 Different Storage Times
Mohammad Alamri ABEFG 1, Mohammed E. SayedDOI: 10.12659/MSM.947361
Med Sci Monit 2025; 31:e947361
Table 1 Materials, brands, manufacturers, and specifications used for the study.
| Material | Manufacturer | Types |
|---|---|---|
| Occlufast Rock | Zhermak, Badia Polesine, Italy | Lot No.: 419353 (Conventional IOR)WT=30s, ST=60s, H=95, DR=20 μm, DS=7D |
| Occlufast CAD | Zhermak, Badia Polesine, Italy | Lot No.: 404891; CAD IOR (scannable)WT=30 s, ST=60 s, H=95, DR=20 μm, DS=7D |
| Virtual CADBite | Virtual CADBite, ivoclar vivadent, Amherst, NY, USA | Lot No.: ZL09W7; CAD IOR (no contrast medium required while scanning)Vinylpolysiloxane (20–30%), Methylhydrogensiloxane (5–10%), Organoplatinic complex (0.01–0.05%), Silicon dioxide (40–50%), Pigment (10–20%), Food dyes/aroma (0.1–0.5%)WT=30 s, ST=45 s, H=85, DS=1.5% linear change, DR=2 μm |
| Flexitime Bite | Kulzer, South Bend, IN, USA | Lot No.: K010133 (CAD IOR)WT=30 s, ST=60 s, H=90, DS=1.5% linear change, DR=2 μm |
| Maxill Bite | Maxill, Cortland, OH, USA | Lot No.: 85500522 (Clear IOR)WT=30 s, ST=75 s |
| CharmFlex Bite | Nongshim-ro, Gunpo-si, Gyeonggi-do, Korea | Lot No.: 58123003 (Clear IOR)WT=30 s, ST=60 s, ER=99.9%, H=90Dispenser D2 (50-mL cartridge) |
| Defend ClearBite | Defend, Wendt Street Algonquin, IL, USA | Lot No.: 85500123 [Clear IOR (regular set)]Polydimethylsiloxane vinyl terminated (20–40%), Dimethylsiloxane copolymer (1–10%), Quartz silica (30–50%), Polysiloxane (<5%)WT=60 s, ST=60 s, H=60–65,Mousse-like and Thixotropic, polyvinyl siloxaneVisibility for voids or bubbles |
| MD 520 | Durr Dental, Kornwestheim, Germany | Lot No.: 2214103Combination of aldehydes, quaternary ammonium cations, special surfactants, and excipients in aqueous solution. 100 g MD 520 contain 0.5 g glutaraldehyde, 0.25 g alkyl benzyl dimethyl ammonium chlorideDisinfection time=10 M; pH: 4.3±0.5 |
| IOR – interocclusal registration material; WT – working time; ST – setting time; ER – elastic recovery; H(shoreA) – hardness, DR – detail reproduction; DS – dimensional stability; D – days; M – minutes; CAD – computer aided diagnosis (scannable IOR); Clear IOR – transparent material that shows voids and defects, | ||