In Vitro Assessment of Linear Dimensional Accuracy of Polyvinyl Siloxane-Based Computer-Aided Design and Transparent Interocclusal Record Materials at 3 Different Storage Times

Mohammad Alamri ABEFG 1, Mohammed E. Sayed ORCID logo ABEFG 2, Bandar M.A. Al-Makramani ABEFG 2*, Praveen Gangadharappa ABEFG 2, Mohammed M. Al Moaleem BCDEF 2, Saad S. AlResayes ORCID logo CDEFG 3, Nisreen Nabiel Hassan ORCID logo CDEFG 4, Mai Almarzouki CDEFG 5, Manal A. Daish CDEFG 6, Futoon Abdulkareem Yankisar CDEFG 7, Sarah Q. Hasousah CDEFG 8, Areej T. Alqahtani CDEFG 8, Mohammed A. Alfaifi ORCID logo CDEFG 9, Mohammed Ayoub CDEFG 6, Khurshid Mattoo ACDEF 2

DOI: 10.12659/MSM.947361

Med Sci Monit 2025; 31:e947361

Table 2 One-way ANOVA test results showing comparative differences in mean values between 2 different interocclusal registration (IOR) materials (CAD and transparent) and their respective subgroups at different periods (1 day, 3 days, 7 days).

MaterialIOR typeSubgroupTime interval (h)nMeanSDF statisticP value
CAD IOR (Code C) (n=180)Occlufast CAD (group CO)CO1 h1524.920.03531.62610.1936
CO11 day1524.910.0319
CO33 days1524.900.0313
CO77 days1524.890.0318
Virtual CADBite (group CV)CV1 h1524.940.03352.74020.0491*
CV11 day1524.930.0341
CV33 days1524.920.0329
CV77 days1524.900.0508
Flexitime Bite (group CF)CF1 h1524.870.04650.65870.5809
CF11 day1524.860.0416
CF33 days1524.850.0438
CF77 days1524.850.0431
Transparent IOR (Code T) (n=180)Maxill Bite (group TM)TM1 h1524.940.02473.65080.0178*
TM11 day1524.930.0214
TM33 days1524.920.0214
TM77 days1524.910.0223
CharmFlex Bite (group TC)TC1 h1524.920.03590.70840.5511
TC11 day1524.910.0344
TC33 days1524.910.0351
TC77 days1524.900.0347
Defend ClearBite (group TD)TD1 h1524.920.02572.39850.07756
TD11 day1524.910.0258
TD33 days1524.910.0258
TD77 days1524.900.0249
IOR – interocclusal registration material; n – number; SD – standard deviation; F – variation between sample means/variation within the samples.
Tests used: 1. Levene test = to assess equality of variances 2. Shapiro-Wilk test = data distribution for normality 3. One way ANOVA = using f distribution (right-tailed) to testing hypothesis and determining statistical differences between various sub groups.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.