26 March 2025 : Clinical Research
Balancing Image Quality and Iodine Intake: Insights from CT Spectral Imaging of the Portal Vein
Linjie Huang ABCDEF 1, Shengchen Jiang CD 1, Fengqiu Ruan C 2, Liling LongDOI: 10.12659/MSM.947391
Med Sci Monit 2025; 31:e947391
Table 3 Comparison of objective scores of 40–140 keV image quality in Group A.
| Extra-hepatic portal vein | Intra-hepatic portal vein | |||||||
|---|---|---|---|---|---|---|---|---|
| CT values | Image noise | CNR | SNR | CT values | Image noise | CNR | SNR | |
| 40 keV | 367.14±53.10 | 41.07±5.24 | 8.51±1.60 | 9.05±1.47 | 349.24±58.70 | 41.39±6.73 | 3.77±1.11 | 8.52±1.26 |
| 50 keV | 254.37±35.49 | 29.59±3.79 | 7.65±1.42 | 8.71±1.42 | 244.38±38.35 | 29.62±4.59 | 3.30±0.88 | 8.33±1.17 |
| 60 keV | 185.51±25.19 | 22.59±2.84 | 6.53±1.29 | 8.32±1.36 | 181.07±27.13 | 22.55±3.33 | 2.85±0.80 | 8.11±1.15 |
| 70 keV | 141.77±20.51 | 18.29±2.30 | 5.40±1.25 | 7.87±1.44 | 141.16±20.09 | 18.03±2.58 | 2.35±0.69 | 7.91±1.12 |
| 80 keV | 115.35±14.88 | 15.61±1.93 | 4.48±1.05 | 7.74±1.99* | 115.67±15.88 | 15.20±2.16 | 1.89±0.65 | 7.70±1.11 |
| 90 keV | 97.29±12.53 | 13.81±1.72 | 3.61±0.99 | 7.15±1.22 | 98.74±12.73 | 13.38±1.85 | 1.49±0.58 | 7.47±1.11 |
| 100 keV | 84.67±11.02 | 12.57±1.56 | 2.84±0.94 | 6.84±1.19 | 86.84±10.87 | 12.11±1.65 | 1.12±0.58 | 7.26±1.12 |
| 110 keV | 75.67±10.08 | 11.68±1.44 | 2.26±0.95 | 6.58±1.17 | 78.56±9.62 | 11.20±1.54 | 0.82±0.59 | 7.11±1.13 |
| 120 keV | 69.53±9.44 | 11.03±1.38 | 1.70±0.93 | 6.40±1.16 | 72.80±8.73 | 10.60±1.46 | 0.57±0.61 | 6.97±1.14 |
| 130 keV | 64.64±9.02 | 10.46±1.23 | 1.27±0.93 | 6.26±1.11 | 68.23±8.10 | 10.13±1.40 | 0.37±0.64 | 6.84±1.15 |
| 140 keV | 60.87±8.72 | 10.22±1.27 | 0.91±0.94 | 6.05±1.15 | 64.67±7.62 | 9.76±1.36 | 0.21±0.67 | 6.73±1.16 |
| P value | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 |
| Except where indicated, data are presented as means±standard deviations (SD). * Data are expressed as median±interquartile range. p | ||||||||