Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

23 March 2025 : Clinical Research  

Intraoperative Renal Near-Infrared Spectroscopy Monitoring as a Predictor of Renal Outcomes in Cardiac Surgery

Buket Özyaprak ORCID logo ABCDEFG 1*, Yılmaz Apaydın ORCID logo ABC 1, Şule Balk ORCID logo BCD 2, Mehmet Gamlı ORCID logo CDE 1, Abdulkadir İskender ORCID logo DEF 3, Gürcan Güler ORCID logo EFG 1, Damla Bozan Güler ORCID logo ABC 1, Ayşe Neslihan Balkaya ORCID logo BCD 1, Tuğba Onur ORCID logo CDEF 1, Canan Yılmaz ORCID logo DEF 1, Ümran Karaca ORCID logo EFG 1, Filiz Ata ORCID logo AFG 1, Yusuf Ata ORCID logo BCD 4, Gönül Erkan ORCID logo CEF 5, Nail Kahraman ORCID logo DFG 6

DOI: 10.12659/MSM.947462

Med Sci Monit 2025; 31:e947462

Table 3 Comparison of percent changes in NIRS values at intraoperative time points between patients with and without acute renal failure.

Without ARF=Group 1 (n=313)With ARF=Group 2 (n=44)P value
T0–T1 percent change, (mean±SD)0.005±0.04−0.02±0.05a
T0–T2 percent change, (mean±SD)−0.05±0.05−0.10±0.06a
T0–T3 percent change, (mean±SD)−0.16±0.06−0.27±0.05a
T0–T4 percent change, (mean±SD)−0.07±0.05−0.18±0.06a
T0–T5 percent change, (mean±SD)−0.04±0.05−0.14±0.06a
a Mann-Whitney U test.
SD – standard deviation; n – number; p

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.