Table 5 Hemodynamic changes after induction.

TimeHeart rate (bpm)Systolic arterial blood pressure (mmHg)
Group D (n=36)Group R (n=37)p valueGroup D (n=36)Group R (n=37)p value
Mean±SDMean±SDMean±SDMean±SD
Baseline79.39±12.8578.57±10.760.768139.83±16.15141.38±12.350.647
Before 1min63.17±9.9368.89±9.87127.22±13.34116.14±7.37
After 1 min64.11±9.9369.68±9.85123.00±12.72114.84±7.19
2 min65.31±10.2867.14±9.640.435118.81±12.45111.16±6.99
3 min66.17±10.4564.22±8.900.393115.58±12.54108.14±6.75
4 min67.17±10.6862.14±8.47111.97±11.75107.59±7.010.056
5 min67.53±10.6861.41±8.22111.17±11.89106.30±6.95
Baseline100.17±11.24101.46±9.500.59780.31±11.6181.51±10.500.642
Before 1min91.81±10.1882.19±6.3174.08±10.8665.24±7.61
After 1 min89.25±9.8582.43±5.9672.36±10.6166.14±7.60
2 min85.92±9.0779.70±5.6269.53±9.3864.03±7.13
3 min82.81±8.9376.81±5.10b66.53±9.2161.22±6.36
4 min79.78±8.4276.46±5.2063.67±8.7760.86±6.700.129
5 min79.00±8.4775.59±5.2862.83±8.7660.19±6.640.150
Group1: Propofol-Dexmedetomidine, Group 2: Propofol-Remifentanil. Group effect: p=0.961Time effect: Group*Time effect: repeated measures ANOVA results for Heart rate. Group effect: Time effect: Group*Time effect: repeated measures ANOVA results for Systolic arterial blood pressure. Group effect: Time effect: Group*Time effect: repeated measures ANOVA results for Mean arterial blood pressure. Group effect: Time effect: Group*Time effect: repeated measures ANOVA results for Diastolic arterial blood pressure. In comparing the time effect within the group, superscripts expressed with different letters indicate that there is a statistically significant.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.