02 June 2025 : Clinical Research
Effects of Air Conditioning-Induced Humidity Reduction on Glomerular Filtration Rate in Healthy Adults
Xiang Li CE 1, Yaohui Ma BCD 1, Gaosi Xu AG 1*DOI: 10.12659/MSM.948310
Med Sci Monit 2025; 31:e948310
Table 2 eGFR values calculated by MDRD and CKD-EPI formulas in both groups.
| Type of study | Air conditioning | Fan | P | |
|---|---|---|---|---|
| eGFR, mL/min per 1.73 m2 | ||||
| Mean±SD | ||||
| Cross-sectional | MDRD | 105.3±16.5 | 109.1±17.0 | <0.001 |
| CKD-EPI | 106.0±12.7 | 107.8±12.7 | <0.001 | |
| Self-control | MDRD | 104.6±15.8 | 108.4±15.7 | <0.001 |
| CKD-EPI | 105.4±12.4 | 107.4±11.8 | <0.001 | |
| eGFR – estimated glomerular filtration rate; MDRD – Modification of Diet in Renal Disease; CKD-EPI – Chronic Kidney Disease Epidemiology Collaboration. | ||||