16 October 2025 : Clinical Research
Comprehensive Analysis of Risk Factors for Recurrence in Women of Reproductive Age Undergoing Hysteroscopic Polypectomy
Serap Fırtına TuncerDOI: 10.12659/MSM.950098
Med Sci Monit 2025; 31:e950098
Table 2 Logistic regression analysis of factors for predicting endometrial polyp recurrence.
| Coefficient | SE | Wald | df | P | OR | 95% CI for OR | ||
|---|---|---|---|---|---|---|---|---|
| Lower | Upper | |||||||
| LNG-IUS treatment | −3.135 | 0.41 | 58.566 | 1 | <0.001 | 0.043 | 0.019 | 0.097 |
| Adenomyosis | 2.332 | 0.344 | 46.074 | 1 | <0.001 | 10.297 | 5.251 | 20.188 |
| PCOS | 2.196 | 0.585 | 14.080 | 1 | <0.001 | 8.990 | 2.855 | 28.312 |
| BMI ≥30 kg/m | 2.163 | 0.334 | 41.969 | <0.001 | 8.698 | 4.521 | 16.736 | |
| Tamoxifen use | 1.806 | 0.584 | 9.551 | 1 | 0.002 | 6.088 | 1.936 | 19.140 |
| Leiomyoma uteri | 1.389 | 0.320 | 18.859 | 1 | <0.001 | 4.012 | 2.143 | 7.509 |
| SE – standard error; df – degree of freedom; OR – odds ratio; LNG-IUS – levonorgestrel-releasing intrauterine system; PCOS – polycystic ovarian syndrome. Explanations: The Hosmer-Lemeshow goodness-of-fit test yielded a value of 0.704, indicating no significant deviation between the model-predicted probabilities and observed outcomes, thereby supporting adequate calibration of the logistic regression model. A value close to 1 indicates a good fit, while a value significantly different from 1 suggests a poor fit. | ||||||||