Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

23 December 2025 : Clinical Research  

Body Weight and Range of Motion as Predictors of Trunk Asymmetry in Children With Spinal Muscular Atrophy: A Prospective Functional Assessment

Ewa Gajewska ORCID logo ABCDEF 1*, Aleksandra Bieniaszewska ORCID logo ABE 1, Magdalena Sobieska ORCID logo CDE 2

DOI: 10.12659/MSM.950590

Med Sci Monit 2025; 31:e950590

Table 2 BMI, BMI z-score, and body status values according to z-scores for patients with spinal muscular atrophy divided according to functional status and trunk parameters. For walkers only, min–max values are given due to the low number. The difference between first and second examinations was calculated using the Wilcoxon test; z and P values are shown.

ParameterExaminationNon-sitters, n=9Sitters, n=23Walkers, n=6; min-max
BMI valueFirst13.1±2.016.1±4.714.6–25.8
Second13.3±2.116.2±4.814.5–25.5
Difference 1 vs 2 examination−0.32; 0.758−0.11; 0.9140.53; 0.617
BMI z-scoreFirst−3.87±2.56−1.45±2.37−0.45–2.14
Second−3.45±3.02−1.62±2.41−0.55–1.89
Difference 1 vs 2 examination0.32; 0.7590.95; 0.3522.10; 0.089
Body status according to BMI z-score, [the number of patients]First: Underweight7100
 Healthy weight194
 Overweight111
 Obesity031
Second: Underweight6120
 Healthy weight374
 Overweight031
 Obesity011
Number of patients with a change in BMI category260
CR-RFirst69±1068±1460–90
Second58±1968±1460–90
Difference 1 vs 2 examination1.52; 0.1280.13; 0.8960.94; 0.345
CR-LFirst60±3474±1070–90
Second68±2176±1380–85
Difference 1 vs 2 examination0.40; 0.6860,86; 0.3900.94; 0.342
SATR-UFirst6±23±30
Second5±23±30–3
Difference 1 vs 2 examination0.36; 0.7150.45; 0.653--
SATR-LFirst6±24±40
Second5±43±30–4
Difference 1 vs 2 examination0.45; 0.6650.20; 0.8421.34; 0.180
CR-R – right side cervical rotation; CR-L – left cervical rotation; SATR-U – upper trunk rotation angle; SATR-L – lower trunk rotation angle.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.