17 July 2026 : Laboratory Research
Evaluation of the Trueness and Precision of Cast, Milled-Cast, Milled, and 3D-Printed Post-and-Core Techniques Using Matching Software: An In Vitro Study
Majed S. AltomanDOI: 10.12659/MSM.953491
Med Sci Monit 2026; 32:e953491
Table 1 Summary of mean (SD) values for trueness (RMS), precision, and clinical tolerance of post-and-core restorations fabricated by conventional casting, milled wax-cast, CAD/CAM-milled zirconia, and 3Dprinted zirconia.
| Group | n | RMS (mm) | Precision (mm) | Clinical tolerance (%) |
|---|---|---|---|---|
| I (conventional cast) | 10 | 0.299 (0.047) | 0.289 (0.043) | 3.9 |
| II (milled wax-cast metal) | 10 | 0.722 (0.014) | 0.564 (0.036) | 0.7 |
| III (CAD/CAM-milled zirconia) | 10 | 0.729 (0.017) | 0.462 (0.026) | 1.8 |
| IV (3D-printed zirconia) | 10 | 0.760 (0.013) | 0.426 (0.046) | 0.9 |
| SD, standard deviation; RMS, root mean square; CAD/CAM, computer-aided design/computer-aided manufacturing. | ||||