01 May 2023: Clinical Research

Evaluation of Preoperative Magnetic Resonance Imaging Parameters with Arthroscopic Validation of Subscapularis Tendon Abnormalities in 187 Patients at a Single Center in Turkey

Gokhan Ilyas 1ABE* , Gokhan Senyuva 2CD , Fikri Burak Ipci 3F

DOI: 10.12659/MSM.939772

Med Sci Monit 2023; 29:e939772

Table 3 Comparison of measured parameters in the 2 groups (rupture and non-rupture).

Rupture groupNon-rupture groupP valueCut-off value
CHD mean±SD (range) (mm)6.87±0.6 (5.3–7.8)7.8±0.77 (6.3–10.7)
CHA mean±SD (range) (degree)109±4.4 (98–119)105.2±5.8 (90.5–121)
CGA mean±SD (range) (degree)131.7±4.7 (122–143)133.3±4.2 (122–142)0.11
CO mean±SD (range) (mm)18.22±2.01 (14.2–21.3)13.7±2.73 (11.3–18.2)
CBGA mean±SD (range) (degree)63.2±8.5 (43–85)64±9.5 (42–95)
LTA mean±SD (range) (degree)32.55±1.9 (27–38)31.81±1.35 (28–38)
CA mean±SD (range) (degree)103.6±8.6 (82–117)117.2±7.1 (88–129)
CHD – coraco-humeral distance; CHA – coraco-humeral angle; CGA – coraco-glenoid angle; CO – coracoid overlap; CBGA – coracoid-body glenoid angle; LTA – lesser tuberosity angle; CA – coracoid angle; SD – standard deviation.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.