07 September 2023 : Clinical Research
Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
Rongji Ma1ABCEF, Atik Badshah Shaikh2BCDEF, Qinxin Zhang1ABCEF, Xiuyun Su2CDE, Yonghua Wang1BC, Fuhai Pan2BC, Jianwen Chen2ACDEG, Kai He2ABCDEG*DOI: 10.12659/MSM.940300
Med Sci Monit 2023; 29:e940300
Table 3 Finite element analysis results of Sanders type II B calcaneal fractures.
| Fixation methods | Stress of internal fixation (MPa) | Stress of fracture block (MPa) | Displacement (μm) | Relative displacement (μm) | |||
|---|---|---|---|---|---|---|---|
| Maximum | Minimum | Maximum | Minimum | Medial | Lateral | ||
| Screw group | 48.120 | 0.053 | 13.470 | 0.014 | 11.226 | 11.230 | 4.000 |
| Plate group | 36.890 | 0.029 | 13.036 | 0.0015 | 11.287 | 11.283 | 4.300 |