07 September 2023 : Clinical Research
Comparative Biomechanical Analysis of Anterior Process Locking Plate Alone versus Combined with Percutaneous Cannulated Screw Fixation for Sanders Type II Calcaneal Fractures: A Finite Element Study
Rongji Ma1ABCEF, Atik Badshah Shaikh2BCDEF, Qinxin Zhang1ABCEF, Xiuyun Su2CDE, Yonghua Wang1BC, Fuhai Pan2BC, Jianwen Chen2ACDEG, Kai He2ABCDEG*DOI: 10.12659/MSM.940300
Med Sci Monit 2023; 29:e940300
Table 4 Finite element analysis results of Sanders type II C calcaneal fractures.
| Fixation methods | Stress of internal fixation (MPa) | Stress of fracture block (MPa) | Displacement (μm) | Relative displacement (μm) | |||
|---|---|---|---|---|---|---|---|
| Maximum | Minimum | Maximum | Minimum | Medial | Lateral | ||
| Screw group | 46.270 | 0.059 | 14.000 | 0.013 | 10.491 | 10.491 | 0.200 |
| Plate group | 66.621 | 0.049 | 13.550 | 0.014 | 10.500 | 10.501 | 1.000 |