03 August 2023>: Article
Comparative Analysis of Fused Deposition Modeling and Digital Light Processing Techniques for Dimensional Accuracy in Clear Aligner Manufacturing
Wojciech Grzebieluch 1ACDEF* , Magdalena Grajzer 2BDE , Marcin Mikulewicz 3ABDEFDOI: 10.12659/MSM.940922
Med Sci Monit 2023; 29:e940922
Table 3 Measurement locations and algorithms used to analyze distortions.
Measurement location | Range | Abbr. | Used algorithm* | Value (+/−) and deformation |
---|---|---|---|---|
46 – buccal surface | 46 | 46 X | C2C absolute distance[2D1/2 Triangulation] k=6 (X)** | (+) arch bended lingually, (−) arch displaced buccally** |
46 – mesio-buccal cusp | 46 | 46 Z | C2C absolute distance[2D1/2 Triangulation] k=6 (Z)** | (+) displaced occlusally, (−) displaced apically** |
36 – buccal surface | 36 | 36 X | C2C absolute distance[2D1/2 Triangulation] k=6 (X)** | (+) arch bended buccally, (−) arch displaced lingually** |
36 – mesio-buccal cusp | 36 | 36 Z | C2C absolute distance[2D1/2 Triangulation] k=6 (Z)** | (+) displaced occlusally, (−) displaced apically** |
31 – labial surface | 31 | 31 Y | C2C absolute distance[2D1/2 Triangulation] k=6 (Y)** | (+) moved lingually, (−) moved labially** |
31 – incisal margin | 31 | 31 Z | C2C absolute distance[2D1/2 Triangulation] k=6 (Z)** | (+) displaced occlusally, (−) displaced apically** |
* CloudCompare, 2.13.alpha (); ** positive or negative values measured along axis (X or Y or Z). |