Influence of Chairside Simulated Adjustment (Finishing and Polishing) Protocol and Chlorhexidine Mouthwash Immersion on Color Stability and Translucency of 2 and 3 Preshaded Multilayered Monolithic Zirconia

Mohammed E. Sayed ORCID logo1ACDEG*, Saurabh Jain ORCID logo1ABDEF, Abrar A. Ageeli ORCID logo2BCEFG, Alhanouf K. Alnajdi ORCID logo3BCEFG, Asma Ahmed Zain ORCID logo3BCEFG, Maimonah Alali ORCID logo3BCEFG, Abdulaziz Ali Ahmed Alhazmi ORCID logo3BCEFG, Ebrahim Fihaid Alsubaiy ORCID logo4ADEFG, Abdullah Hasan Alshehri ORCID logo4ACDEG, Ahid Amer Alshahrani ORCID logo5CDEFG, Mohammad Alamri ORCID logo6CDEFG, Mohammed H. Al Wadei ORCID logo6CDEFG, Hossam F. Jokhadar ORCID logo7ACDEG, Khurshid Mattoo ORCID logo1ACDEF

DOI: 10.12659/MSM.943404

Med Sci Monit 2024; 30:e943404

Table 1 List of materials, instrumentation, and manufacturer.

S. NoMaterials/InstrumentsManufacturerSpecifications/features
1.Nacera Pearl Multi-Shade (HT) (Code – NPM)Doceram Medical Ceramics GmbH, Hesslingsweg Dortmund, Germany
2.Ceramill Zolid FX Multilayer (HT) (Code – CZM)Amann Girrbach (AG), Koblach, Austria
3.Diasynt Plus, Diacera (EVE)Ernst Vetter, Pforzheim, Germany
4.SUNSUN, Oberflächentechnik GmbH, Ölbronn-Dürrn Germany
5.Ceramill Motion 2/5x, Amann Girrbach, Ceramill Therm SAmann Girrbach (AG), Koblach, Austria
6.Nacera Clean LTDoceram Medical GmbH, Germany
7.Nacera CalibrateDoceram Medical GmbH, Germany
8.Nacera Pearl shellDoceram Medical GmbH, Germany
9.Nacera Shine ZrDoceram Medical Gmbh, Germany
10.Colorimeter (CS-10, Portable colorimeter)Hangzhou Quality Lab Scientific Co. Ltd., Hangzhou, China
HT – highly translucent; GmbH – Gesellschaft mit beschränkter Haftung (Company with limited liability); rpm – rotations per minute; mm – millimeter.
* Number of the finishing bur;
§ Size of the tool;
Δ – Color change differences; L (Value) indicates light or dark; 100/0=completely white/completely black; C (chroma) indicates red–green and H (hue) indicates yellow–blue chromatic coordinates with each coordinate designated a positive (+) and a negative sign (−), which in turn denotes the examined color is in which direction example [C=green (−C), and red (+C) axis, and H=blue (−H), and yellow (+H) axis]; A=corresponding chromatic coordinate for chroma on CIELAB scale; B=corresponding chromatic coordinate for hue on CIELAB scale; E=delta value for color difference.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.