Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

15 March 2020 : Animal Research  

Use of Electrical Impedance Tomography (EIT) to Estimate Global and Regional Lung Recruitment Volume (VREC) Induced by Positive End-Expiratory Pressure (PEEP): An Experiment in Pigs with Lung Injury

Yu-Mei Wang1BE, Xiu-Mei Sun1C, Yi-Min Zhou1B, Jing-Ran Chen1B, Kun-Ming Cheng1B, Hong-Liang Li1F, Yan-Lin Yang1D, Linlin Zhang1DE, Jian-Xin Zhou1AG*

DOI: 10.12659/MSM.922609

Med Sci Monit 2020; 26:e922609

Abstract

BACKGROUND: Electrical impedance tomography (EIT) is a real-time tool used to monitor lung volume change at the bedside, which could be used to measure lung recruitment volume (VREC) for setting positive end-expiratory pressure (PEEP). We assessed and compared the agreement in VREC measurement with the EIT method versus the flow-derived method.

MATERIAL AND METHODS: In 12 Bama pigs, lung injury was induced by tracheal instillation of hydrochloric acid and verified by an arterial partial pressure of oxygen to inspired oxygen fraction ratio below 200 mmHg. During the end-expiratory occlusion, an airway release maneuver was conduct at 5 and 15 cmH₂O of PEEP. VREC was measured by flow-integrated PEEP-induced lung volume change (flow-derived method) and end-expiratory lung impedance change (EIT-derived method). Linear regression and Bland-Altman analysis were used to test the correlation and agreement between these 2 measures.

RESULTS: Lung injury was successfully induced in all the animals. EIT-derived VREC was significantly correlated with flow-derived VREC (R²=0.650, p=0.002). The bias (the lower and upper limits of agreement) was –19 (–182 to 144) ml. The median (interquartile range) of EIT-derived VREC was 322 (218–469) ml, with 110 (59–142) ml and 194 (157–307) ml in dependent and nondependent lung regions, respectively. Global and regional respiratory system compliance increased significantly at high PEEP compared to those at low PEEP.

CONCLUSIONS: Close correlation and agreement were found between EIT-derived and flow-derived VREC measurements. The advantages of EIT-derived recruitability assessment included the avoidance of ventilation interruption and the ability to provide regional recruitment information.

Keywords: Electric Impedance, Positive-Pressure Respiration, Respiration, Artificial, Respiratory Mechanics, Feasibility Studies, Lung Injury, Monitoring, Physiologic, Swine, Swine, Miniature, Tidal Volume, Tomography

Add Comment 0 Comments

Editorial

01 April 2025 : Editorial  

Editorial: Rapid Testing for the Avian Influenza A(H5N1) Virus is Urgently Required as Infections in Poultry and Dairy Cows are on the Rise, and so is Transmission to Humans

Dinah V. Parums

DOI: 10.12659/MSM.949109

Med Sci Monit 2025; 31:e949109

0:00

In Press

Review article  

Global Guidelines and Trends in HPV Vaccination for Cervical Cancer Prevention

Med Sci Monit In Press; DOI: 10.12659/MSM.947173  

0:00

Clinical Research  

Serum Prolidase and Ischemia-Modified Albumin Levels in Neural Tube Defects: A Comparative Study of Myelome...

Med Sci Monit In Press; DOI: 10.12659/MSM.947873  

0:00

Clinical Research  

Impact of Depression, Fatigue, and Pain on Quality of Life in Slovak Multiple Sclerosis Patients

Med Sci Monit In Press; DOI: 10.12659/MSM.947630  

Clinical Research  

Longitudinal Evaluation of Metabolic Benefits of Inactivated COVID-19 Vaccination in Diabetic Patients in T...

Med Sci Monit In Press; DOI: 10.12659/MSM.947450  

0:00

Most Viewed Current Articles

17 Jan 2024 : Review article   7,960,158

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   702,953

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   29,945

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   23,915

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750