12 October 2023 : Laboratory Research  

Comparative Analysis of Properties in Chairside Silicone Denture Liners versus Heat-Cured Molloplast-B: An In-Depth In Vitro Evaluation

Mahdi Mutahar1ABCDE*, Nasser M. Al Ahmari2DFG, Saeed M. Alqahtani2DFG, Thrya S. Gadah2BFG, Abdulkarim H. Alshehri3DFG, Hafiz A. Adawi3EG, Mansoor Shariff2FG, Fuad A. Al-Sanabani3FG, Mohammed M/ Al Moaleem ORCID logo34EF

DOI: 10.12659/MSM.941793

Med Sci Monit 2023; 29:e941793

Abstract

0:00

BACKGROUND: We investigated the bond strength, tensile strength, and water absorption properties of 4 widely used chairside silicone long-term denture soft lining materials and compared properties with those of heat-cured silicone material.

MATERIAL AND METHODS: Four chairside materials (GC Reline Soft, Mucopren Soft, Sofreliner Soft, and Elite Soft Relining) and a heat-cured silicone material (Molloplast B) were investigated. For tensile and shear bond strength and tensile strength, samples were prepared according to the manufacturers’ instructions and the testing machine used. For water absorption, IOS 1567 was followed to prepare specimens. Bond strengths were measured using a Lloyd Instruments materials testing machine. Ten specimens for each test were prepared for each soft liner, except for water absorption and solubility tests, for which only 5 specimens were prepared. ANOVA, Bonferroni, and Kruskal-Wallis tests were used to compare values of materials and assess changes over time.

RESULTS: There was strong evidence of differences in the properties between materials. GC Reline Soft showed comparable tensile bond (1.4±0.6 MPa), shear bond (1.1±0.4 MPa), tensile strength (5.44±0.98), water absorption (0.92±0.2 µg/mm³), and solubility values (0.3±0.2 µg/mm3) to that of Molloplast B (1.4±0.4; 1.6±0.5; 4.53±0.9 MPa, 1.7±0.3, and 1.0±0.3 µg/mm³, respectively). The water solubility of Sofreliner Soft was significantly lower (1.5±0.8 µg/mm³) than that of Molloplast B.

CONCLUSIONS: There were significant differences between some properties of 4 chairside denture soft lining materials and that of Molloplast B, which had higher shear and tensile bond strength than chairside denture silicone soft lining materials but had the highest water solubility.

Keywords: Absorption, Denture Liners, Shear Strength, Solubility, Tensile Strength, Hot Temperature, Materials Testing, Silicone Elastomers, Water, Denture Bases, Surface Properties, Dental Bonding

Add Comment 0 Comments

Editorial

01 December 2024 : Editorial  

Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical Research

Dinah V. Parums

DOI: 10.12659/MSM.947428

Med Sci Monit 2024; 30:e947428

0:00

In Press

Review article  

Impact of Traditional Chinese Medicine Antioxidants on Oxidative Stress and Drug-Induced Liver Injury: A Re...

Med Sci Monit In Press; DOI: 10.12659/MSM.945147  

Meta-Analysis  

Reliability of Extraoral Scanners in Capturing 3D Geometry for Dental Prostheses: A Systematic Review

Med Sci Monit In Press; DOI: 10.12659/MSM.946470  

Review article  

Skin Barrier Dysfunction in Acne Vulgaris: Pathogenesis and Therapeutic Approaches

Med Sci Monit In Press; DOI: 10.12659/MSM.945336  

Clinical Research  

Comparative Efficacy of Unilateral Biportal Endoscopy vs Traditional Surgery in Lumbar Degenerative Disorders

Med Sci Monit In Press; DOI: 10.12659/MSM.946468  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,957,156

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,969,425

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   697,045

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   263,088

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750