Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

04 April 2019 : Clinical Research  

Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study

Jun-Song Yang1EF, Baorong He1C, Fang Tian1B, Tuan-Jiang Liu1B, Peng Liu1F, Jia-Nan Zhang1C, Shi-Chang Liu1D, Yuan Tuo1F, Lei Chu2F, Ding-Jun Hao1AG*

DOI: 10.12659/MSM.913124

Med Sci Monit 2019; 25:2479-2487

Abstract

BACKGROUND: With the in-depth development of minimally invasive spine surgery in recent years, robot- and computer-assisted technologies have been increasingly used and successfully applied to spinal surgery.

MATERIAL AND METHODS: We performed a retrospective analysis of 60 patients with grade I or II lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) from January 2017 to December 2017. A robot-assisted surgical system was used in 30 patients for pedicle screw placement. The other 30 patients underwent fluoroscopy-guided percutaneous pedicle screw placement.

RESULTS: There were 130 screws placed under fluoroscopic guidance, with 26.2% penetration of the pedicle wall. There were 130 screws placed in robotic-assisted surgery, with 6.2% penetration of the pedicle wall. Severe screw deviation (Neo grade III) was identified in 4 screws in the fluoroscopy-guided group, while no severe deviation was noted in the robot-assisted group. In the fluoroscopic group, 15.6% of screws penetrated the superior articular process, and 2.1% screws had severe complications (Babu grade III). However, only 5.1% of screws in the robot-assisted group had severe complications. The mean screw insertion angle was significantly greater in the robot-assisted group than in the fluoroscopy-guided group (23.8±6.1° vs. 18.4±7.2°, P=0.017).

CONCLUSIONS: Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the following advantages: greater accuracy, lower incidences of screw penetration of the pedicle wall and invasion of the facet joints, and better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis.

Keywords: Orthopedic Fixation Devices, Robotics, Spine, spondylolisthesis, Cohort Studies, Lumbar Vertebrae, Lumbosacral Region, Minimally Invasive Surgical Procedures, Pedicle Screws, Robotic Surgical Procedures, Spinal Fusion, Surgery, Computer-Assisted

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Association Between Total Cholesterol–to–High-Density Lipoprotein Ratio and Gestational Hypertension: A Cas...

Med Sci Monit In Press; DOI: 10.12659/MSM.952395  

Review article  

Clinical Use of Endotracheal Intubation Without Neuromuscular Blockade: The Current Stage of Knowledge

Med Sci Monit In Press; DOI: 10.12659/MSM.951765  

Clinical Research  

Effect of Dexmedetomidine Hydrochloride Nasal Spray on Anxiety and Sleep in Patients Undergoing Gynecologic...

Med Sci Monit In Press; DOI: 10.12659/MSM.952465  

Clinical Research  

Prognostic Value of Mortality Scoring Systems in Patients With Severe Burns: Identifying Key Predictors of ...

Med Sci Monit In Press; DOI: 10.12659/MSM.951713  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,173

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,757,769

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,143

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,797

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750