Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

09 November 2019 : Clinical Research  

Bioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients

Se-Hee Yoon12ABCDEFG*, Seul-gi Kim3ABCDE, In-Beom Jeong1AD, Won-Min Hwang1AD, Sung-Ro Yun1AD

DOI: 10.12659/MSM.918095

Med Sci Monit 2019; 25:8438-8446

Abstract

BACKGROUND: Hypernatremia is associated with poor outcomes in critically ill patients, and an accurate assessment of water volume is important to determine appropriate fluid hydration. Bioelectrical impedance analysis (BIA) is a new, noninvasive, and relatively easy method for measuring hydration status. This study aimed to investigate whether bioelectrical impedance measurements of body water could reduce the frequency of blood sampling for fluid replacement in patients with hypernatremia.

MATERIAL AND METHODS: Fifty-one hospitalized patients were studied with hypernatremia, defined as a serum sodium ≥150 mmol/L determined by laboratory testing. Laboratory and BIA measurements were compared, and water deficiency was calculated with a conventional formula (sodium-corrected Watson formula) and measured by BIA.

RESULTS: The value of the absolute fluid overload (AFO) equivalent to the overhydration (OH) value, determined using BIA, did not accurately represent water deficit in patients with hypernatremia (r=0.137, P=0.347). Although the total body water (TBW) measured by BIA showed a significant correlation with that determined by the conventional formula (r=0.861, P<0.001), there was a proportional bias (r=0.617, P<0.001). The intracellular water (ICW) measured by BIA underestimated the TBW level calculated by the conventional formula by about 14.06±4.0 L in the Bland-Altman analysis.

CONCLUSIONS: It is not currently possible to replace blood testing with BIA for assessing volume status in hypernatremic patients. However, ICW value measured by BIA might represent plasma sodium level more accurately than extracellular water (ECW) or TBW value in patients with hypernatremia.

Keywords: Body Fluids, Dehydration, Electric Impedance, Hypernatremia, Body Composition, Body Water, Extracellular Space, Organism Hydration Status, Water

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Review article  

Clinical Use of Endotracheal Intubation Without Neuromuscular Blockade: The Current Stage of Knowledge

Med Sci Monit In Press; DOI: 10.12659/MSM.951765  

Clinical Research  

Effect of Dexmedetomidine Hydrochloride Nasal Spray on Anxiety and Sleep in Patients Undergoing Gynecologic...

Med Sci Monit In Press; DOI: 10.12659/MSM.952465  

Clinical Research  

Prognostic Value of Mortality Scoring Systems in Patients With Severe Burns: Identifying Key Predictors of ...

Med Sci Monit In Press; DOI: 10.12659/MSM.951713  

Laboratory Research  

Evaluation of the Trueness and Precision of Cast, Milled-Cast, Milled, and 3D-Printed Post-and-Core Techniq...

Med Sci Monit In Press; DOI: 10.12659/MSM.953491  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,214

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,757,839

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,153

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,809

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750