11 December 2013: Product Investigations  

The effect of cleaning substances on the surface of denture base material

Juozas Žilinskas ADEF , Jonas Junevičius CDEF , Kęstutis Česaitis BEG , Gabrielė Junevičiūtė BEF

DOI: 10.12659/MSM.889568

Med Sci Monit 2013; 19:1142-1145

0 Comments

Abstract

BACKGROUND: The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material.

MATERIAL AND METHODS: Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, “plates”). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste (“Colgate Total”), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning.

RESULTS: No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (p<0.05changed) – the reflection became poorer. The plates were most affected by the medium-bristle toothbrush with baking soda – the total reflection reduction was 4.82±0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect – 4.6±0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface – 3.89±0.07%.

CONCLUSIONS: All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

Keywords: Materials Testing - methods, Denture Bases, Methylmethacrylates, Sodium Bicarbonate - adverse effects, Spectrum Analysis, Surface Properties - drug effects, Toothbrushing - adverse effects, Toothpastes - adverse effects

Background

In clinical practice, patients frequently ask their physicians about removable denture care, which is often insufficient and sometimes is absent altogether). A questionnaire-based survey was conducted at Lithuanian University of Health Sciences (LUHS) Clinic of Orthopedic Odontology. The survey showed that patients most frequently used wet toothbrushes for the care of their dentures, with sodium chloride (table salt), sodium hydrogen carbonate (baking soda), or toothpaste “Colgate Total” applied as cleaning substances. The participants of the survey stated that they usually cleaned their dentures 3 times per day for 1–2 minutes each time.

Even though there are various denture care techniques such as disinfecting tablets, disinfection with microwaves or ozone [1–3], or plaque removal with ultrasound [4], these techniques are not as common as toothbrush use is. Patients do not realize that the use of cheap additional substances available in every household may damage their dentures. Increasing rough surface area and the number of scratches result in multiple micro-retention zones that accumulate microorganisms and cause formation of dental calculi on the dentures. All these changes in dentures may result in mucosal irritation and halitosis [5,6]. This causes psychological discomfort, nausea, and social problems [7]. In some cases, patients discontinue regular use of their dentures, and eventually they become ill-fitting. The aim of the study was to evaluate the possible damage to the dentures caused by denture care measures, and to develop recommendations concerning the care of removable dentures.

Material and Methods

Plates with all the characteristics of removable denture bases were produced from heat-polymerized acrylic resin Meliodent Heat Cure (Heraeus-Kulzer, Germany) used for denture manufacturing; the plates were produced following the polymerization regimen set by the manufacturer. Polishing and buffing of the plates was carried out following the removable denture production standards; the plates were then cut into 1.5×5 cm strips, which were numbered. Following that, each strip was assigned hard-, medium-, or soft-bristled toothbrushes (Oral-B Complete) with additional cleaning substances. The following groups were formed:

Reflection measurements of the plates were conducted prior to the testing and after 2 and 6 hours. This test was conducted in quintuplicate.

A device imitating tooth brushing movements was constructed. Within 1 minute it performed 100 reciprocal movements with the amplitude of 1.5 cm, and with 2.4 N pressure force of the toothbrush on the plate. The plates were monitored with a USB4000 (OceanOptics) spectrometer by measuring surface reflection in 2 wavelengths: 250–400 nm – for small scratches, and 600–800 nm – for large scratches. During the denture cleaning simulation, a new 0.5 g dose of the abrasive substance and 0.5 mL of water were reapplied on the plates every 10 minutes. The plates were placed in a holder under the spectrometer so that their measured areas would coincide.

During each studied exposure, 708 automatic spectrometry measurements were performed at the wavelength of 250–400 nm in each plate. Every plate was examined prior to the simulation, and after 2 and 6 hours of testing. In total, the monitoring of each studied plate yielded 2124 reflection measurements of different points of the evaluated surface. At the wavelength of 600–800 nm, 1075 spectrometry measurements were performed in each plate. In total, 3225 reflection measurements of different points of the evaluated surface were obtained from each studied plate after the simulation sequence.

Results

The evaluation of differences in plate surface reflection showed that all abrasive substances altered the reflection. Evaluation of the mean values by applying the dispersion analysis, ANOVA, and Tukey’s method showed no statistically significant difference between the results of the 5 tests (p>0.05). Statistically significant (p<0.05) changes were observed in all studied plates after the tooth brushing simulation (Table 1).

Medium-bristle toothbrushes inflicted most damage when used with baking soda (NaHCO3) – they reduced the surface reflection by 4.82±0.1%. Table salt inflicted the least damage when applied on a medium-bristle toothbrush – the surface reflection reduction was 3.5±0.16% (Figure 1).

When comparing the effect of toothbrushes with toothpaste (“Colgate Total”) applied, the least damage was observed with a soft-bristled toothbrush – the surface reflection decreased by 3.01±0.12% (p>0.05). The most damage was inflicted with a hard-bristled toothbrush – the surface reflection reduction was 4.6±0.05%.

When testing medium-bristle toothbrushes, the fewest small scratches were detected with the tested toothpaste – the surface reflection dropped by 2.7±0.11%. The greatest number of large scratches was found when using baking soda – the surface reflection reduction was 3.38±0.2%.

Discussion

Removable denture care has been actively researched for a number of years, yet the number of articles in the literature suitable for this study was scarce. More attention is usually paid to denture attrition, its mass reduction, or measurement of microgrooves left by toothbrushes [8,9]. The results of our study were based on changes in plate surface reflection, indicating the general wear of the denture surface.

Other authors found no statistical difference between scratches inflicted by various toothbrushes on the surface of different heat polymerized acrylic resins [9]. In our study, we used heat-polymerized acrylic resin, Meliodent Heat Cure (Heraeus-Kulzer, Germany). This would mean that the results of the study should be irrespective of the manufacturer of the heat -polymerized acrylic resin.

Acording to some authors the main difference between artificial teeth and denture base materials is the incorporation of tooth-colored pigments rather than pink ones. The Vickers hardness number (VHN) of both materials is 20 [10]. Because there is no difference in the hardness, there were no tests conducted to test the acrylic teeth wear caused by the toothbrush.

The technique of this study was based on the questionnaire survey data concerning the most common hygienic denture care techniques used by 110 patients with removable dentures. The study simulated all variants of the additional substances used in the cleaning of dentures, taking into account the most common use of medium-bristle toothbrushes. Surveyed patients indicated that they mostly used “Colgate Total” toothpaste for denture cleaning. To evaluate the effect of toothbrushes with different brush head types on the surface of the acrylic resin, soft-bristled and hard-bristled toothbrushes were used in the test with toothpaste.

When constructing the device that imitated tooth brushing, we tried to reproduce the actual movements of the toothbrush in the oral cavity, thus the rotational movement (which causes grater surface changes) was replaced with the reciprocal movement [11]. The toothbrush was pressed against the surface with a force of 2.4 N; the selection of such force was based of the mean value of the force most frequently applied during tooth brushing [9,12,13]. The toothbrush movement speed (50 mm/s) was selected on the basis of in vivo studies, where it ranged between 30 and 150 mm/s [14,15].

The results of our study confirmed that baking soda has stronger abrasive characteristics compared to table salt, although both substances are of equal hardness according to the Mohs scale – 2.5 [16]. The literature also describes baking soda as a strong abrasive substance [17]. This is associated with the crystal structure and a better solubility of NaCl in water (35.89 g/100 g water at 20°C), compared to NaHCO3 (9.6 g/100 g water at 20°C) [18]. The residual amount of undissolved crystals causes changes in the surface of the acrylic resin. We also noticed that table salt was rather aggressive during the first 2 hours, but later on its abrasiveness dropped due to the dissolution and consequent shrinking of its sharp crystals. In other words, more rounded crystals moved between the bristles of the toothbrush and the surface of the plate, thus reducing the abrasiveness of table salt.

Conclusions

In removable denture care, all mechanical cleaning techniques that involve toothbrush use have a negative effect on the denture base surface, yet the use of chemical measures alone is insufficient. When using toothpaste, hard-bristled toothbrushes cause the greatest surface damage. The usage of baking soda is not recommended for removable denture care. Soft-bristled toothbrushes are the best for cleaning removable dentures. Physicians should re-polish removable dentures during their patients’ periodic visits.

References

1. Silva-Lovato HC, Wever B, Andriaens E, Clinical and antimicrobial efficacy of NitrAdine™ based disinfecting cleaning tablets in complete denture wearers: J Appl Oral Sci, 2010; 18(6); 560-65, pmid: 21308285

2. Ribeiro DG, Pavarina AC, Dovigo LN, Denture disinfection by microwave irradiation: A randomized clinical study: J Dent, 2009; 37; 666-72, pmid: 19481327

3. Azarpazhooh A, Limeback H, The application of ozone in dentistry: A systematic review of literature: J Dent, 2008; 36(2); 104-16, pmid: 18166260

4. Gwinnett AJ, Caputo L, The effectiveness of ultrasonic denture cleaning: A scanning electron microscope study: J Prosthet Dent, 1983; 50(1); 20-25, pmid: 6576152

5. Baran I, Nalçacı R, Self-reported denture hygiene habits and oral tissue conditions of complete denture wearers: Arch Gerontol Geriatr, 2009; 49(2); 237-41, pmid: 18976822

6. Whitehead KA, Verran J, The effect of surface topography on the retention of microorganisms: Food and Bioproducts Processing, 2006; 84(4); 253-59

7. Allis JT, Leopold DA, Smell and taste disorders: Facial Plast Surg Clin North Am, 2012; 20(1); 93-111, pmid: 22099622

8. Harrison A, Jagger RDC: Prim-Dent-Care, 1997; 4; 21-24, pmid: 10332342

9. Richmond R, Macfarlane TV, McCord JF, An evaluation of the surface changes in PMMA biomaterial formulations as a result of toothbrush/dentifrice abrasion: Dental Materials, 2004; 20; 124-32, pmid: 14706795

10. McCabe JF, Walls AVG: Applied dental materials, 2008; 119-33

11. Turssi CP, Ferracane JL, Serra MC, Abrasive wear of resin composites as related to finishing and polishing procedures: Dent Mater, 2005; 21(7); 641-48, pmid: 15978273

12. Lewis R, Dwyer-Joyce RS, Pickles MJ, Interaction between toothbrushes and toothpaste abrasive particles in simulated tooth cleaning: Wear, 2004; 257; 368-76

13. West NX, Hooper SM, O’Sullivan D: J Dent, 2012; 40(1); 77-85, pmid: 22051246

14. Phaneuf EA, Harrington JH, Dale PP, Shklar G, Automatic toothbrush: a new reciprocating action: J Am Dent Assoc, 1962; 65; 12-25, pmid: 14486169

15. Allen CR, Hunsley NK, MacGregor IDM, Development of a force-sensing toothbrush using PIC micro-controller technology for dental hygiene: Mechatronics, 1996; 6(2); 125-40

16. Ridgway RR, Ballard AH, Bailey BL, Hardness values for electrochemical products: Journal of Electrochemical Society, 1933; 63(1); 369-93

17. Banerjee A, Hajatdoost-Sani M, Farrell S, Thompson I, A clinical evaluation and comparison of bioactive glass and sodium bicarbonate air polishing powders: J Dent, 2010; 38(6); 475-79, pmid: 20223272

18.

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750