Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

08 September 2003

Comparison of prescribed and delivered doses of dialysis using anthropometrically and bioelectrically measured patient volumes

Wojciech T. Załuska, Daniel Schneditz, Andrzej Swatowski, Andrzej Jaroszyński, Andrzej Książek

Med Sci Monit 2003; 9(9): CR405-410 :: ID: 13193

Abstract

Background:One of the uncertainties in the prescription of dialysis dose, measured as Kt/V for urea (Kt/Vu), is the volume of urea distribution (V). The aim of our study was to compare two different approaches to estimating V and Kt/V, respectively, and to compare the predicted (prescribed) dose with the actually delivered dose, measured by urea kinetics.Material/Methods:V was estimated using anthropometric measures with the Watson formula (VWatson), and also by multi-frequency bioimpedance analysis (VBIS). Both volumes were determined for the state at the end of dialysis and ultrafiltration, and then used to predict (prescribe) Kt/VWatson and Kt/VBIS, respectively. The delivered Kt/Vu was determined from pre- and postdialysis urea concentrations.Results:209 patients were studied in 254 measurements. VWatson and VBIS correlated significantly (VBIS=0.64*VWatson+15.03, r2=0.67) but VWatson (36.0I6.4 L) was higher than VBIS (32.5I8.1 L). The bias between techniques was 3.5I4.6 L. As a consequence of volume underestimation, Kt/VBIS was overestimated (1.44I0.38) when compared to the actually delivered Kt/Vu (1.28I0.32). However, Kt/VWatson (1.27I0.25) based on VWatson was almost identical to the actually delivered treatment dose.Conclusions:The close correspondence between the delivered and predicted (prescribed) dose of dialysis using anthropometric volumes leads to the conclusion that in this study kinetic distribution volume was best described by VWatson. The overestimation of prescribed dialysis dose based on bioimpedance analysis suggests caution in the use of bioimpedance volumes, because of the risk of prescribing inadequate dialysis.

Keywords: Renal Dialysis - methods

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750