Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

15 May 2014 : Original article  

Anatomical study of suboccipital vertebral arteries and surrounding bony structures using virtual reality technology

Wenbo HaEF, DeLin YangBD, Shixin GuAG, Qi-Wu XuDE, Xiaoming CheBF, Jin-Song WuDF, Wensheng LiAG

DOI: 10.12659/MSM.890840

Med Sci Monit 2014; 20:802-806

Abstract

BACKGROUND: This work aimed to evaluate the efficacy of virtual reality (VR) technology in neurosurgical anatomy through a comparison of the virtual 3D microanatomy of the suboccipital vertebral arteries and their bony structures as part of the resection of tumors in the craniovertebral junction (CVJ) of 20 patients compared to the actual microanatomy of the vertebral arteries of 15 cadaveric headsets.

MATERIAL AND METHODS: The study was conducted with 2 groups of data: a VR group composed of 20 clinical cases and a physical body group (PB group) composed of 15 cadaveric headsets. In the VR group, the dissection and measurements of the vertebral arteries were simulated on a Dextroscope. In the PB group, the vertebral arteries in the cadaver heads were examined under a microscope and anatomical measurements of VA and bony structures were performed. The length and course of the vertebral arteries and its surrounding bony structures in each group were compared.

RESULTS: The distances from the inferior part of the transverse process foramen (TPF) of C1 to the inferior part of TPF of C2 were 17.68±2.86 mm and 18.4±1.82 mm in the PB and VR groups, respectively. The distances between the middle point of the posterior arch of the atlas and the medial intersection of VA on the groove were 17.35±2.23 mm in the PB group and 18.13±2.58 mm in the VR group. The distances between the middle line and the entrance of VA to the lower rim of TPF of Atlas were 28.64±2.67 mm in PB group and 29.23±2.89 mm in VR group. The diameters of the vertebral artery (VA) at the end of the groove and foramen of C2 transverse process were 4.02±046 mm and 4.25±0.51 mm, respectively, in the PB group and 3.54±0.44 mm and 4.47±0.62 mm, respectively, in VR group. The distances between the VA lumen center and midline of the foramen magnum at the level of dural penetration was 10.4±1.13 mm in the PB group and 11.5±1.34 mm in the VR group (P>0.05).

CONCLUSIONS: VR technology can accurately simulate the anatomical features of the suboccipital vertebral arteries and their bony structures, which facilitates the planning of individual surgeries in the CVJ.

Keywords: Virtual Reality Exposure Therapy, Neurosurgical Procedures - methods, Occipital Lobe - blood supply, Spine - anatomy & histology, User-Computer Interface, Vertebral Artery - anatomy & histology

0 Comments

Editorial

01 February 2023 : Editorial  

Editorial: The XBB.1.5 (‘Kraken’) Subvariant of Omicron SARS-CoV-2 and its Rapid Global Spread

Dinah V. Parums
Science Editor, Medical Science Monitor, International Scientific Information, Inc., Melville, NY, USA

DOI: 10.12659/MSM.939580

Med Sci Monit 2023; 29:e939580

SARS-CoV-2/COVID-19

19 January 2023 : Clinical Research  

Evaluation of Health-Related Quality of Life and Mental Health in 729 Medical Students in Indonesia During ...

Med Sci Monit In Press; DOI: 10.12659/MSM.938892  

27 December 2022 : Clinical Research  

Effect of Physiotherapy to Correct Rounded Shoulder Posture in 30 Patients During the COVID-19 Pandemic in ...

Med Sci Monit 2022; 28:e938926

10 December 2022 : Clinical Research  

Retrospective Study to Identify Risk Factors for Severe Disease and Mortality Using the Modified Early Warn...

Med Sci Monit 2022; 28:e938647

In Press

02 Feb 2023 : Clinical Research  

Online Questionnaire-Based Study to Evaluate the Attitudes and Use of Rubber Dental Dams by Saudi Dental Pr...

Med Sci Monit In Press; DOI: 10.12659/MSM.938672  

02 Feb 2023 : Database Analysis  

Prognostic-Related Biomarkers in Pancreatic Ductal Adenocarcinoma Correlating with Immune Infiltrates Based...

Med Sci Monit In Press; DOI: 10.12659/MSM.938785  

01 Feb 2023 : Clinical Research  

Comparison of 3 Enzyme-Linked Immunoassay Methods to Evaluate Serum Concentrations of Infliximab and Antibo...

Med Sci Monit In Press; DOI: 10.12659/MSM.939084  

31 Jan 2023 : Clinical Research  

Balloon Dilation Eustachian Tuboplasty Combined with Tympanotomy Tube Insertion for Treatment of Refractory...

Med Sci Monit In Press; DOI: 10.12659/MSM.938879  

Most Viewed Current Articles

13 Nov 2021 : Clinical Research  

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

30 Dec 2021 : Clinical Research  

Retrospective Study of Outcomes and Hospitalization Rates of Patients in Italy with a Confirmed Diagnosis o...

DOI :10.12659/MSM.935379

Med Sci Monit 2021; 27:e935379

08 Mar 2022 : Review article  

A Review of the Potential Roles of Antioxidant and Anti-Inflammatory Pharmacological Approaches for the Man...

DOI :10.12659/MSM.936292

Med Sci Monit 2022; 28:e936292

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750