Logo Medical Science Monitor

Call: +1.631.470.9640
Closed: National Holiday

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

23 February 2016 : Clinical Research  

Dose Evaluation of Fractionated Schema and Distance From Tumor to Spinal Cord for Spinal SBRT with Simultaneous Integrated Boost: A Preliminary Study

Hao YangABCDEFG, Bo-ning CaiBC, Xiao-shen WangA, Xiao-hu CongA, Wei XuA, Jin-yuan WangA, Jun YangBC, Shou-ping XuA, Zhong-jian JuA, Lin MaADEFG

DOI: 10.12659/MSM.897146

Med Sci Monit 2016; 22:598-607

Abstract

BACKGROUND: This study investigated and quantified the dosimetric impact of the distance from the tumor to the spinal cord and fractionation schemes for patients who received stereotactic body radiation therapy (SBRT) and hypofractionated simultaneous integrated boost (HF-SIB).

MATERIAL AND METHODS: Six modified planning target volumes (PTVs) for 5 patients with spinal metastases were created by artificial uniform extension in the region of PTV adjacent spinal cord with a specified minimum tumor to cord distance (0–5 mm). The prescription dose (biologic equivalent dose, BED) was 70 Gy in different fractionation schemes (1, 3, 5, and 10 fractions). For PTV V100, Dmin, D98, D95, and D1, spinal cord dose, conformity index (CI), V30 were measured and compared.

RESULTS: PTV-to-cord distance influenced PTV V100, Dmin, D98, and D95, and fractionation schemes influenced Dmin and D98, with a significant difference. Distances of ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm from PTV to spinal cord meet dose requirements in 1, 3, 5, and 10 fractionations, respectively. Spinal cord dose, CI, and V30 were not impacted by PTV-to-cord distance and fractionation schemes.

CONCLUSIONS: Target volume coverage, Dmin, D98, and D95 were directly correlated with distance from the spinal cord for spine SBRT and HF-SIB. Based on our study, ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm distance from PTV to spinal cord meets dose requirements in 1, 3, 5 and 10 fractionations, respectively.

Keywords: Radiosurgery - methods, Dose Fractionation, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Spinal Cord - surgery, Spinal Cord Neoplasms - surgery

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Body Weight and Insulin Resistance Indicators Among Children

Med Sci Monit In Press; DOI: 10.12659/MSM.951434  

Clinical Research  

Comparison of Radiographic Cervical Sagittal Alignment Parameters in Patients With Nonspecific Neck Pain, D...

Med Sci Monit In Press; DOI: 10.12659/MSM.952950  

Clinical Research  

Combined Fibrinogen and Urinary α1-Microglobulin as Predictors of Respiratory Tract Infection in Children w...

Med Sci Monit In Press; DOI: 10.12659/MSM.951066  

Database Analysis  

Evaluation of Salivary Total Oxidant Status (TOS) and Total Antioxidant Status (TAS) in Orthodontic Patient...

Med Sci Monit In Press; DOI: 10.12659/MSM.952052  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,175,576

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,756,620

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,465,966

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,651

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750