Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

21 November 2016 : Clinical Research  

Evaluation of Pediatric Liver Transplantation-Related Artery Complications Using Intra-Operative Multi-Parameter Ultrasonography

Xiuyun RenABCDEF, Junhui GuanBCD, Nong GaoBCD, Hong NiuBCD, Jie TangAG

DOI: 10.12659/MSM.897408

Med Sci Monit 2016; 22:4495-4502

Abstract

BACKGROUND: This article discusses the value of using multi-parameter evaluation of intra-operative ultrasonography in evaluating pediatric liver transplantation-related arterial complications.

MATERIAL AND METHODS: Sixty-eight children receiving a liver transplant underwent intraoperative ultrasonography for monitoring of artery hemodynamics. The ultrasonic measurement parameters included the diameters of the hepatic artery (HA) of the donor and anastomotic stoma, peak systolic velocity (PSV), resistance index (RI), acceleration time (SAT), and blood flow volume.

RESULTS: After being treated immediately using surgery or other means, blood flow returned to normal in 8 cases, and did not in 3 cases, of whom 2 experienced postoperative HAT. There was a significant difference in HA diameter of the donor, anastomotic stoma diameter, PSV, RI, SAT, and blood flow volume before and after treatment of the donor in the complications group. Postoperative complications occurred in 7 of 68 recipients, including the 2 cases exhibiting complications during the surgery (complication group) and 5 without complications during the surgery (no complication group). There was a statistically significant difference (P<0.05) between the 2 groups in intraoperative ultrasonography parameters of HA diameter, anastomotic stoma diameter, RI, and blood flow volume.

CONCLUSIONS: Through intraoperative multi-parameter ultrasonic measurement, a definite diagnosis of hepatic artery complications can be made in liver transplantation patients. HA diameter of the donor, anastomotic stoma diameter, PSV, RI, SAT, and blood flow volume are important in assessing intraoperative artery complications.

Keywords: Child, Preschool, Child, Hepatic Artery - surgery, Infant, Newborn, Liver Diseases - etiology, Liver Transplantation - methods, Postoperative Complications - diagnostic imaging, Ultrasonography - methods

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750