Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

08 February 2017 : Clinical Research  

Imaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture

Jinpeng Gong12ABCDEF, Pengcheng Liu1ABCDEF, Ming Cai3ABCDEFG*

DOI: 10.12659/MSM.899280

Med Sci Monit 2017; 23:719-724

Abstract

BACKGROUND: Proximal femoral nail anti-rotation (PFNA) is a standard femoral intertrochanteric fracture operation. Iatrogenic vascular injury, although uncommon, is a reported complication of PFNA surgery as well as a complication of hip fracture surgery. This study aimed to compare the safety and best use of the distal locking screw in 170 mm PFNA and 240 mm PFNA devices, and to determine the safe region for placement of the distal locking screw in PFNA surgery.

MATERIAL AND METHODS: A retrospective analysis of 100 patients with 170 mm PFNA and 80 patients with 240 mm PFNA were retrospectively analyzed. Two levels of PFNA distal locking screws were equally divided into three planes: I, II, III, for 170 mm PFNA devices and i, ii, iii for the 240 mm PRNA devices. The medial half of the femur was equally divided into eight regions: A to H. The distance between the outer femur and the superficial, the deep and the perforating femoral arteries (SFAs, DFAs, and PFAs), and angles between the reference line and the connection line between the femur center to each artery were measured.

RESULTS: SFAs and DFAs but not PFAs were found in risky or hazardous regions, and DFAs were obviously closer to the femur than SFAs and PFAs at the same level. In the region within 10 mm of the femur, no SFAs were found. The short nails (170 mm PFNA-II devices) were the closest to the DFAs region, indicating that the 170 mm PFNA-II nails are most likely to cause special vessel injury. The short nails were relatively more distant from the SFAs, which were located posteriorly to the long nails (240 mm PFNA-II).

CONCLUSIONS: The distal locking screw of the 170 mm PFNA device was more prone to damage the femoral deep artery when the two types of PFNA devices are compared in patients who were candidates for both types of devices.

Keywords: Bone Screws, Femoral Artery, Femoral Fractures, Safety

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750