Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

05 April 2017 : Clinical Research  

Initial Experience with Aortic Valve Replacement via a Minimally Invasive Approach: A Comparison of Stented, Stentless and Sutureless Valves

Johanna Konertz1ABCDEFG, Konstantin Zhigalov1ABCDEFG, Alexander Weymann2ABCDEFG*, Pascal M. Dohmen23ABCDEFG

DOI: 10.12659/MSM.901780

Med Sci Monit 2017; 23:1645-1654

Abstract

BACKGROUND: This study aimed to compare the short-term outcomes of MIS-AVR among 3 different types of biological heart valves.

MATERIAL AND METHODS: Complete data were obtained from 79 patients who underwent MIS-AVR between January 2010 and June 2015. Patients were divided into 3 groups: 27 patients (group A) received Medtronic 3f® (Medtronic Inc., Fridley, MN, USA), 36 patients (group B) received DokimosPlus® (LabCor Laboratórios Ltda., Belo Horizonte, Brazil) and 16 patients (group C) received Perceval® (Sorin Biomedica Cardio S.r.l., Saluggia VC, Italy) valves. Operative and postoperative parameters such as duration of operation, bypass time, duration of ventilation, morbidity, and mortality were statistically analyzed using the Kruskal-Wallis test. Hemodynamic assessment with transthoracic echocardiography was performed before discharge.

RESULTS: The EuroSCORE II ranged between 0.67 and 6.94 with no significant difference between the groups. The median operative time was 166 min (range 90–230 min) in total, with significantly shorter times in group C (120 min [range 90–200]). The median total ventilation time was significantly lower in group C and significantly higher in group A. Hemodynamic evaluation demonstrated a mean maximal velocity (vmax) over the aortic valve of 2.3 m/s (range 0.9–4.3 m/s) with average mean and peak pressure gradient values of 10 mmHg (range 3–24 mmHg) and 20 mmHg (range 5–42 mmHg), respectively. Group A showed the highest values for vmax (H>5.99). No significant difference was found regarding duration of hospitalization. Mortality was 3%.

CONCLUSIONS: In conclusion, all 3 valves showed good perioperative results, satisfying hemodynamic performance, and low complication rates.

Keywords: Aortic Valve, Aortic Valve Insufficiency, Surgical Procedures, Minimally Invasive

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750