Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

16 May 2017 : Clinical Research  

Diagnosis of Congenital Coarctation of the Aorta and Accompany Malformations in Infants by Multi-Detector Computed Tomography Angiography and Transthoracic Echocardiography: A Chinese Clinical Study

Fang Huang1ABCF*, Qiang Chen2ABCE, Wen-han Huang1BD, Hong Wu1BD, Wei-cheng Li1BD, Qing-quan Lai1BDG

DOI: 10.12659/MSM.901928

Med Sci Monit 2017; 23:2308-2314

Abstract

BACKGROUND: The purpose of this study was to evaluate the utility of multi-detector computed tomography (MDCT) angiography and transthoracic echocardiography (TTE) in the diagnosis of congenital coarctation of the aorta (CoA) and accompanying malformations in infants.

MATERIAL AND METHODS: From January 2012 and December 2015, we enrolled 68 infants with clinically suspected CoA who underwent MDCT angiography and TTE in our hospital. Surgical correction was conducted to confirm the diagnostic accuracy of both examinations in all patients.

RESULTS: In this study, the diagnosis of CoA was confirmed infants by surgical results in 55 of 68 infants. The diagnostic accuracy, sensitivity, and specificity of MDCT angiography were 95.6%, 96.4%, and 92.3%, respectively. The diagnostic accuracy, sensitivity, and specificity of TTE were 88.2%, 90.9%, and 76.9%, respectively. There was no significant difference in diagnostic accuracy, sensitivity, and specificity between MDCT angiography and TTE (χ²=2.473, p>0.05, χ²=1.373, p>0.05 and χ²=1.182, p>0.05, respectively). In the diagnosis of concomitant cardiac abnormalities with CoA, the 2 methods also play different roles.

CONCLUSIONS: MDCT angiography and TTE play different roles in the diagnosis of CoA and accompany malformations. MDCT angiography in the diagnosis of the extra-cardiac vascular malformations is better than TTE, and TTE is superior to MDCT angiography in diagnosing intracardiac malformation. Combined MDCT angiography and TTE is a relatively valuable, reliable, and noninvasive method in the diagnosis of CoA and accompany malformations in infants.

Keywords: Aortic Coarctation, Echocardiography, Doppler, multidetector computed tomography

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750